Introduction; Specifications - Empire Heating Systems SR-6BC-3 Installation Instructions And Owner's Manual

Unvented room heater
Table of Contents

Advertisement

Instructions to Installer
1. Installer must leave instruction manual with owner after
installation.
2. Installer must have owner fill out and mail warranty card supplied
with unvented room heater.
3. Installer should show owner how to start and operate unvented
room heater.
Always consult your local Building Department regarding regulations,
codes or ordinances which apply to the installation of an unvented
room heater.
General Information
This appliance is design certified in accordance with American
National Standards Institute Z21.11.2 and CR94-001 for use in
British Columbia or Manitoba by the Canadian Standards Association
Laboratories as an Unvented Room Heater and shall be installed
according to these instructions.
Any alteration of the original design, installed other than as
shown in these instructions or use with a type of gas not
shown on the rating plate is the responsibility of the person
and company making the change.
Important
All correspondence should refer to complete Model Number, Serial
Number and type of gas.
Well Head Gas Installations
Some natural gas utilities use "well head" gas. This may affect the
Btu output of the unit. Contact the gas company for the heating value.
Contact the manufacturer or your gas company before changing
spud/orifice size.
This appliance is equipped for (natural gas or propane) gas. Field
conversion is not permitted.
Model
Input
BTU/HR (KW/H) Three Plaques
BTU/HR (KW/H) Two Plaques
BTU/HR (KW/H) One Plaque (Nat. Gas)
BTU/HR (KW/H) One Plaque (LP Gas)
Height
Width
Depth
Gas Inlet
Accessories
Blower
Floor Stand
16010-10-0314

INTRODUCTION

WARNING

SPECIFICATIONS

BTU/HR (KW/H) Five Plaques
Qualified Installing Agency
Installation and replacement of gas piping, gas utilization equipment
or accessories and repair and servicing of equipment shall be
performed only by a qualified agency. The term "qualified agency"
means any individual, firm, corporation, or company that either in
person or through a representative is engaged in and is responsible
for (a) the installation, testing, or replacement of gas piping or (b) the
connection, installation, testing, repair, or servicing of equipment;
that is experienced in such work; that is familiar with all precautions
required, and that has complied with all the requirements of the
authority having jurisdiction.
The installation must conform with local codes or, in the absence
of local codes, with the National Fuel Gas Code, ANSI Z223.1/
NFPA54.*
*Available from the American National Standards Institute, Inc., 11
West 42nd St., New York, N.Y. 10036.
High Altitudes
For altitudes/elevations above 2,000 feet (610m) ratings should be
reduced at the rate of 4 percent for each 1,000 feet (305m) above
sea level. Contact the manufacturer or your gas company before
changing spud/orifice size.
SR-6
-
-
6,000 (1.8)
6,000 (1.8)
22" (559mm)
11 7/8" (302mm)
6 1/2" (165mm)
3/8" (10mm)
-
SRS-10
SR-10
-
-
18,000 (5.3)
-
12,000 (3.5)
10,000 (2.9)
6,700 (2)
10,000 (2.9)
6,700(2)
22" (559mm)
22" (559mm)
11 7/8" (302mm)
18" (457mm)
6 1/2" (165mm)
6 1/2" (165mm)
3/8" (10mm)
3/8" (10mm)
-
SRB-18
SRS-10
SRS-18
SR-18
-
-
Page 5