Operation Procedures
Knowledge of the proper operation of the MX3-200H is required to
ensure user safety and efficient performance of the extractor.
SET UP AND OPERATION
1. Electrical Cords:
Two 25' power cords are supplied with the Nautilus MX3-200H. Cord #1 powers vacuum #1, the Solution
Pump, Heater Circuit #1 and the cooling fan; Cord #2 powers vacuum #2, Heater Circuit #2 and the waste
pump if so equipped.
The amperage required by each cord requires that the two cords be plugged into separate circuits:
Use of the MX3-200H with the heater will require operation on two 20amp circuits.
20amp circuits are usually found in kitchens and bathrooms. Operation without the heater will allow
both cords to be connected to separate 15amp circuits. An overloaded circuit will not always trip the circuit
breaker immediately, but it may not provide sufficient voltage for proper operation and the breaker may trip
eventually.
Plug the two power cords into two outlets from different circuits. If the Dual Circuit Indicator green light
fails to light, you may be on the same circuit and may need to select a different plug for one of the cords. If
the Dual Circuit Indicator green light comes on, you are plugged into two different circuits. Proceed with
your set-up procedure.
(Dual Circuit Indicator light may take up to 30 seconds to recognize the two circuits and turn ON.)
If a circuit breaker trips or the pump circuit breaker trips during operation, reset the breakers and move the
cord to another outlet as needed.
until after the pump has been primed and the solution hose and tool have been
connected.
Cord #1
Dual Circuit Indicator Light
When operating the MX3-200H, DO NOT turn the heater on
Cord #2
9