Water Supply & Chemicals - Nautilus MX3-200H Operating Manual

Table of Contents

Advertisement

Water Supply:
• Once the correct metering tip is in place:
o Connect the Auto-Fill Water Supply Hose to the water inlet (the male quick-connect on the front
of the machine.)
o Connect the other end of the hose to a water faucet, and then turn on the water.
• Hot water can be used as long as the temperature does not exceed 140°F.
• Faucet adapter kits (Hydro-Force item #AX21 & AX22) are available that allow connection to different
types of faucets if needed.
Connect the Auto-Fill Water Supply Hose to a
faucet and turn on the water
Connect the Auto-Fill Water Supply Hose to Solution Inlet
(Male quick connect on the front of the machine.)
3/8" id X 25' with F Quick Connect & F Garden Hose Fitting
To adjust the water level in the solution tank:
• Turn off the water supply.
• Adjust the length of the chain connecting the float bottle
to the float valve. Unhook the float from the beaded chain
on the valve. Unsnap the hook from the beaded chain on
the float.
Move the bottle down to decrease the water level.
Move the bottle up to increase the water level.
• Snap the back onto the float chain & hook the float back
onto the valve chain.
• Turn the water supply back on.
If the chemical is not drawing, or if the tank is not filling
or is overflowing, refer to the trouble shooting guide, or
contact your distributor for assistance.
Chemical
Feed Hose
Float Hanger Hook
Float Bottle
12
Float Valve