Measurements And Adjustments; Things To Do After Replacing Ic Or X'tal - Panasonic KX-TG3531BXS Service Manual

Table of Contents

Advertisement

KX-TG3531BXS/KX-TG3531BXB/KX-TG3532BXS/TG3532BXB/KX-TGA351S/KX-TGA351B

12 Measurements and Adjustments

12.1. Things to Do after Replacing IC or X'tal

12.1.1. Preparation
Equipment: Frequency counter
Check Point for measurement: BCK
Checking tolerance: 13.824MHz ± 100Hz (Base Unit)/13.824MHz ± 100Hz (Handset)
12.1.2. Check and Adjust Frequency (Base Unit)
1. Set up Base Unit in TEST mode.
2. Press following keys in order to Adjust Crystal mode. [LOCATOR], [LOCATOR], [LOCATOR], [ ], [CHECK] [ ], [ ]. Check
BCK frequency.
3. If the BCK frequency is out of the checking tolerance (± 100Hz), adjust to Adjustment tolelance (± 30Hz) by pressing [ ] or [ ]
key.
Adjustment Tolerance: 13.824MHz ± 30Hz
4. Press [LOCATOR] key to write the new frequency factor in Memory.
5. Turn the power off. Then this value is available.
Cross Reference:
Test Link Mode for Base Unit (P.44)
12.1.3. Check and Adjust Frequency (Handset)
1. Set DC power supply to 3.9V.
2. Set up Handset in TEST mode (Adjustment flow).
3. Press [1] key to Adjust Crystal mode ("Clock Adj." is displayed on LCD). Check BCK frequency.
4. If the BCK frequency is out of the checking tolerance (± 100Hz), adjust to Adjustment tolelance (± 30Hz) by pressing [ ] or [ ]
key.
Adjustment Tolerance: 13.824MHz ± 30Hz
5. Press [TALK] key to write the new frequency factor in EEPROM.
6. Turn the power off. Then this value is available.
Cross Reference:
RX-CW Test Mode for Handset (P.48)
12.1.4. Adjust Battery Low Detector Voltage (Handset)
After Handset's DSP (IC501) or EEPROM (IC541) replacement, Re-writing Battery Low voltage to EEPROM is required.
With following Handset Adjustment Flow, adjust DC power supply and DC voltmeter by the procedure below.
1. Set DC power supply to 3.9 V.
2. Set up Handset in TEST mode (Adjustment flow).
3. Press [1] key and [OFF] key to Adjust Batt Low mode. ("Bat Adj." is displayed on LCD)
4. Change the voltage of the DC power supply to 3.51 V accurately. Check the voltage at P.C. board pads because some voltage
drops occur due to the usage of long or thin cables.
5. Press [TALK] key twice to write voltage value in EEPROM.
6. Press [TALK] key twice to write charge value 1 in EEPROM.
7. Change the voltage of the DC power supply to 4.50 V accurately.
8. Press [TALK] key twice to write charge value 2 in EEPROM.
9. Turn the power off. Then this value is available.
Note:
Refer to Handset Reference Drawing (P.80) for connection of DC power supply and voltmeter.
Cross Reference:
RX-CW Test Mode for Handset (P.48)