7A. Advanced Process Panel - Lincoln Electric INVERTEC SVM158-A Service Manual

Lincoln electric welding system user manual
Table of Contents

Advertisement

B-5

7A. ADVANCED PROCESS PANEL

(See Figure B.2)
To program Welding modes. SELECT knob is used to
Scroll through all Welding modes. The MEMORY but-
ton is used to store and access Welding modes into
locations M1 thru M8.
Modes:
In addition to the 5 welding modes described in SEC-
TION 7, the Advanced Process Panel allows you to
select the Following additional modes.
• Power Mode
In the Power Mode;
The work point will be in the Volts window. The Amp
window will have CP displayed indicating Constant
Power. Once current starts flowing and during the 5
second "Hold" feature the displays will show Volts
and Amps respectively. Refer to the detailed expla-
nation at the end of this section.
• Gouge
Air Carbon Arc Cutting (CAC-A) is a physical means
of removing base metal or weld metal by using a car-
bon electrode, an electric arc and compressed air.
MEMOR Y BUTTON
MEMOR
(M1 THRU M8)
(M1
SELECT KNOB
(SCOLLS WELDING PR
WELDING PR OCESSES)
OPERATION
ADVANCED PROCESS PANEL VERSION
FIGURE B.2
A
MPS
CONTROL
REMO TE
REMO
TE
LOCAL
LOCAL
SELECT
MEMORY
SELECT
SELECT
V350-PRO
• Pulsed Modes
In Pulse Modes;
The work point will be in the Amps window and
should be set close to the wire feed speed of the
wire feeder in inches per minute. The Volts window
will have SPd displayed indicating Wire Feed
Speed. Once current starts flowing and during the 5
second "Hold" feature the displays will show amps
and volts.
Pulse Mode features that are displayed while select-
ing a Welding pulse mode are listed below;
Steel - .030, .035, .045, .052 – Argon Blends
Stainless Steel - .030, .035, .045 – Argon Blends &
Helium/Argon Blends
Aluminum - .035, 3/64, 1/16 – 4043 & 5356
Metal Core - .045, .052 – Argon Blends
Nickel - .035, .045 – Argon/Helium blends
Refer to the detailed explanation at the end of this
section.
OUTPUT KNOB
V
OLTS
WELD TERMINALS
REMO TE
REMO
TE
ON
ON
OUTPUT
SELECT
ADJUST
B-5
7A
ADJUST KNOB
ADJUST KNOB
(0 THRU 10-HOT START)
(-10 THRU 0 AND
0 THRU +10-ARC CONTROL)
SELECT BUTTON
ON
(HOT START OR ARC CONTROL)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Invertec v350-pro

Table of Contents