SECTION 4
QQ

MECHANICAL ADJUSTMENTS

3 7 63 1515 0
PRECAUTION
1. Clean the following parts with a denatured-alcohol-moistened
swab :
record/playback head
erase head
capstan
2. Demagnetize the record/playback head with a head demagne-
tizer. (Do not bring the head magnetizer close to the erase head.)
3. Do not use a magnetized screwdriver for the adjustments.
4. The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
Torque Measurement
Mode
Torque meter
FWD
CQ-102C
FWD
CQ-102C
Back Tension
FF
CQ-201B
REW
CQ-201B
Tape Tension Measurement
Mode
Tension meter
FWD
CQ-403A
TE
L 13942296513
www
.
http://www.xiaoyu163.com
pinch roller
rubber belts
idlers
Meter reading
30 – 70 g • cm
(0.42 – 0.97 oz • inch)
1.5 – 5.5 g • cm
(0.021 – 0.076 oz • inch)
more than 60 g • cm
(more than 0.83 oz • inch)
more than 60 g • cm
(more than 0.83 oz • inch)
Meter Reading
more than 100 g
(more than 3.53 oz)
x
ao
u163
y
i
– 14 –
http://www.xiaoyu163.com
SECTION 5

ELECTRICAL ADJUSTMENTS

2 9
8

TAPE SECTION

0 dB = 0.775 V
• Standard Output Level
Output terminal
load impedance
output signal level
• Test Tape
Type
Signal
WS-48A
3 kHz, 0 dB
Tape Speed Adjustment
Procedure:
Mode: playback
test tape
WS-48A
(3 kHz, 0 dB)
set
Adjust so that the value on the digital frequency counter is
3,000 Hz.
Q Q
3
6 7
1 3
1 5
Specification Value:
Digital frequency counter
2,910 to 3,090 Hz
Adjust so that the frequency at the beginning and that at the end of
tape winding are between 2,910 to 3,090 Hz.
Adjustment Location:
Tape speed adjustment
co
control inside motor
.
9 4
2 8
HP OUT
32 Ω
0.25 V (–10 dB)
Used for
tape speed adjustment
digital frequency
counter
32 Ω
i jack (J321)
0 5
8
2 9
9 4
2 8
m
9 9
9 9