3 7 63 1515 0

4. Test Mode

4-1 Setting method of the Test Mode

Test Mode
CD MODE
DECK MODE

4-2 Cancel of the test mode

• Initialized and cancel the test mode if pulling out the power cord.
• Cancel the test mode only if the power key is turned off.

4-3 Contents of the Test Mode

• The muting during mode selection is not controlled in the test mode.
• During the test mode, it can be operated in a special manner that is different from an
ordinary operation by using the keys on the main body, specifically as shown in the
following tables
4-4 CD Test Mode
Keys
CD-PLAY/PAUSE
(Cyclically changed the mode
05 and 03 by pressing the key.)
CD STOP
(Cyclically changed in the
stop mode only.)
TE
L 13942296513
SKIP UP
SKIP DOWN
4-5 Deck Test Mode
Keys
TAPE REC
Mechanism half switches indication
The mechanism half switches status are indicated "blank" or "E" in the display.
8th Dot(Display)
Mechanism
Half Switch
ON
OFF
www
.
CIRCUIT DESCRIPTION
Keys
Setting Method
CD PLAY key
Insert the AC cord to AC wall
outlet while holding down the
TAPE PLAY
left key.
✽ ✽
(
✽ ✽
(
Display
• 4 Seconds Recording
If the REC/ARM key is pressed, the system record for 4 seconds.
Then, it rewinds to the REC starting position and plays back automatically.
AUX
If the REC/ARM key is pressed, during the 4 seconds REC operation, the
system records further for 4 seconds, then returns to the starting position
of the first 4 seconds REC operation and plays back.
1st figure
FWD REC Inhibit
Detection SW
Blank
E
x
ao
y
i
8
Display
✽ ✽
✽ ✽
05
:
• Tracking-servo on.
✽ ✽
:
)Time Display
• Pickup moves inward.
✽ ✽
✽ ✽
03
:
• Tracking-servo off. (for checking TE)
✽ ✽
:
)Time Display
• Pickup moves outward.
00 : 00
Stop the CD operation.
Adjustment value/mean value
07 FG/FE
FG value
08 FB/FO
FBAL value /FO value
Q Q
09 TG/TE
3
6 7
TG value
1 3
10 TB/TO
TBAL value /TO value
Ex.0.1~0.2
• Track number up
Ex.0.2~0.1
• Track number down.
Operation
2nd figure
RVS REC Inhibit
Detection SW
Blank
E
u163
.
RXD-M35
2 9
9 4
2 8
Operation
/FE value
1 5
/TE value
0 5
8
2 9
9 4
3rd figure
4th figure
Cassette Half
Tape Play
Detection SW
Detection SW
Blank
E
m
co
9 9
2 8
9 9
Blank
E
5