Model: HRF-800DGS8
Error code lise:
NO
Malfunction
1
normal
2
RT SNR failure
3
F SNR failure
4
R SNR failure
REF defrost sensor failure
5
6
FRZ defrost sensor failure
7
My zone sensor failure
9
failure communication
10
Freezer fan motor failure
11
Cooling fan motor failure
12
REF fan motor failure
13
REF defrost failure
14
FRZ defrost failure
Attention:These error codes cannot be displayed automatically)
E0>EC>Ed>F3>F1>F6>F2>F4>F5>E1>E2>E6
Error
Error code meaning
Indicator
--
RT SNR is short circuit or open
F2
circuit
F SNR is short circuit or open
F3
circuit
R SNR is short circuit or open
F4
circuit
REF defrost sensor is short circuit
F1
or open circuit
FRZ defrost sensor is short circuit
F6
or open circuit
My zone sensor s short circuit or
F5
open circuit
No reflect when setting ,between
display PCB and Power PCB no
E0
signal transmitted over 2 min
E1
Freezer fan motor low rev
Cooling fan motor low rev
E2
REF fan motor low rev
E6
REF defrost display lower 7
REF defrost heater work more zhan
EC
60minute
FRZ defrost display lower 7
FRZ defrost heater work more zhan
Ed
60minute