CLEANING INSTRUCTIONS
The prefilter and collecting cell must be washed on a regular
basis for the Air Cleaner to function at its peak efficiency.
The frequency of cleaning will vary from one environment to
another, therefore the cell should be checked monthly to
determine cleaning schedule. On average, the cell should be
washed every 2-3 months.
COLLECTING CELL AND PREFILTER
1.
Turn Air Cleaner OFF. Remove prefilter and collecting
cell from the Air Cleaner.
2.
Rinse prefilter and cell, and spray completely with DAX
Detergent (or a non-chlorine, non-corrosive, non-
abrasive, liquid household detergent). Let stand for 5
minutes.
Rinse well with hot water (120°F / 49°C
maximum).
3.
If dirt remains, let cell soak in a solution of DAX
Detergent and hot water for 30 minutes.
4.
For drying, place the cell on a 45° angle on one end,
with the arrow pointing sideways, and let stand for 10 -
24 hours. A hair dryer may be used to speed up drying
time.
Make sure the cell is completely dry before
reinserting back into Air Cleaner.
5.
If arcing or snapping occurs or the lights do not come on
when the cell is placed back in the unit and turned on,
then remove the cell and allow to dry longer.
ODOUR & GAS (VOC) FILTER
1.
The Odour & Gas (VOC) Filter must be replaced at
regular
intervals
if
(approximately every 3-6 months).
ODOUR & GAS FILTER IS NOT WASHABLE.
2.
Place grey foam side up, when inserting VOC Filter into
unit.
CABINET
1.
Turn Air Cleaner OFF.
2.
A soft, damp, lint-free cloth may be used to remove dirt
and fingerprints from painted surfaces, grills and side
panels.
NEVER USE AN ABRASIVE CLEANER ON THE
CABINET.
WARNING
DO
NOT
WASH
DISHWASHER.
Never use any object to clean between the cell plates as
this may cause damage to the plates or ionizing wires.
Never place the cell in an oven to dry.
The edges of the cell may be sharp. Handle with care.
DAX Detergent and the Odour & Gas (VOC) Filter are available from
your Dealer.
odour
removal
is
desired
COLLECTING
CELL
TROUBLESHOOTING CHART
PROBLEM
Fan does not operate
Both indicator lights off
Green light on
Red light off
Fan operating
Both lights off
Fan does not operate
Performance light on
Cell arcing excessively
Both indicator lights on
Cell not collecting dirt
The two operation lights are also used as the high voltage
fault indicator. If the fan is operating, but the lights do not
come on, then there is a problem in the high voltage circuit.
To determine the problem, turn the Air Cleaner OFF and
remove the collecting cell. Close the access door and turn
the Air Cleaner back ON. If the lights come back on, the
problem lies in the collecting cell. Check the cell for wetness
from washing or look for a broken ionizing wire or bent cell
plate(s).
If the lights do not come on, the problem is with the power
board or indicator light. If you are unable to correct any of
the above problems, call 1-800-267-8305.
Dimensions
IN
With Castors
Width
Height
Depth
Weight
Input Voltage
Power Consumption
(max)
Air Flow
High
Medium
Low
High
Medium
Low
Cell Output Voltage
Collecting Cell
Surface
Negative Ionizer
Negative Ion Output
Ideal for rooms up to:
(for over 3 air
changes/hour)
CAUSE
Unit not plugged in
Screw not tight on access door
System switch not ON
Negative Ion switch not in ON
position
Cell wet from washing
Short in cell (see below)
Speed selector switch not
positioned correctly
Fan motor malfunction
Cell wet from washing
Cell plate(s) bent
Cell dirty or large lint ball/hair
caught in cell
Broken ionizing wire
Arrow on cell not pointing up

TECHNICAL DATA

19.0 in
25.25 in
14.5 in
52.0 lbs
120 V 60 Hz
220-240 V 50 Hz
110 Watts
With VOC Filter
330 cfm
230 cfm
160 cfm
Without VOC Filter
Without VOC Filter
480 cfm
375 cfm
270 cfm
7500 VDC @ < 1 mA
2079 in²
-5000 VDC @ <.1 mA
3 x 327.7 K/in³
With VOC Filter
28 x 30 x 8 ft
840 ft²
48.3 cm
64.1 cm
36.8 cm
23.6 kg
220 V
60 Hz
With VOC Filter
561 m³/hr
391 m³/hr
272 m³/hr
816 m³/hr
637 m³/hr
459 m³/hr
13413 cm²
3 x 20 K/cm³
With VOC Filter
8.5 x 9.1 x 2.5 m
77.4 m²

Advertisement

loading