Technical Data - Five Seasons DM900UV-VO-A Owner's Manual

Whole-house duct mount hepa air cleaner with ultraviolet lamp & photo catalytic filter
Table of Contents

Advertisement

socket. Remove the lamp from the support
clip. Remove the plastic lamp support clips by
pinching the back of the clip and lightly
pulling away from the reflector.
4. Before replacing the lamps, the reflector
should be cleaned with a soft cloth and mild
non-abrasive soap.
5. Replace the support clips by pressing them
into the hole in the reflector.
6. NEVER use any lamp other than from the
original manufacturer. NEVER run the Air
Cleaner with only one lamp.
7. When replacing the lamp, use gloves to
prevent oil from being deposited on the glass.
Hold the lamp by the base and slide the glass
end into the plastic support clip. Slide the
lamp straight into the lamp socket until the
lamp locks into place.
8. Remove the new PCO filter from the bag and
slide into the upper track under the lamps with
the fuzzy side towards the lamps. During
shipping and handling a small amount of white
dust is created. This can be cleaned by
vacuuming. DO NOT vacuum the filter.
9. Remove the final filter from the bag and slide
it into the track below the PCO filter with the
arrow pointing away from the PCO filter.
10. Replace the lamp access panel tightening all
screws. Do not over tighten.
Note: When the filters are new, you may notice a
new smell from the system. This is normal and
will dissipate within a few hours.
The PCO Filter will discolor with use. This is
normal.
Dimensions
Height
Width
Depth
Intake
Outflow
Unit Weight
Input Voltage
Power Consumption
Air Flow
Cabinet
Power Cord
Filter Dimensions
Ultraviolet Power in Reflector
HEPA Collecting Surface Area

TECHNICAL DATA

14.5 x 3.75 in or 8 in (dia)
14.5 x 4.37 in or 8 in (dia)
Prefilter
HEPA Filter
PCO Filter
Final Filter
PCO
Filter
replaced every 2 years.
Final
Filter
replaced at least once a year.
UV Lamp (#DM900-0191) (2 required): Replace
every 2 years. Includes lamp support clip. The
lamp may still light after 2 years but the intensity
of the germicidal wavelength will be reduced.
UV Lamp / PCO Filter Kit (#DM900-1002): Kit
contains 2 UV lamps, 2 lamp support clips, 1 PCO
filter and gloves.
Always dispose of plastic bags safely. Do not allow
children or pets to play with empty plastic bags.
The lamps used in this air cleaner contain a very small
amount of mercury (Hg). The lamps should be
disposed of according to local ordnances or refer to
www.lamprecycle.org.
The lamps contain a very small amount of mercury
(Hg). In case of accidental breakage, handle with
extreme care. According to the EPA website, open
windows in the affected area and leave the room for 15
minutes. Do not vacuum or use a broom to clean.
Wear a dust mask and use disposable gloves. Scoop
fragments using stiff paper or cardboard. Place
fragments in a plastic bag. Wipe area with damp paper
towels and place towels in the plastic bag. Seal bag
and dispose of waste following local guidelines. Wash
hands with mild detergent and water. See the EPA
website (www.epa.gov) for more information.
29.5 in
16.25 in
12.75 in
47 lbs
120 V
60 Hz
200 Watts
250 CFM
22 gauge
9.0 ft
16 x 12 x 1 in
16 x 12 x 2.5 in
16 x 10 x 0.375 in
16 x 10 x .5 in
>10,000 µW/cm²
40 ft²
7
(#DM900-0450): This must be
(#DM900-0810): This must be
CAUTION
CAUTION
CAUTION
74.9 cm
41.3 cm
32.4 cm
36.8 x 9.5 cm or 20.3 cm (dia)
36.8 x 11.1 cm or 20.3 cm (dia)
21.3 kg
424.8 m³/hr
2.74 m
40.6 x 30.5 x 2.5 cm
40.6 x 30.5 x 5 cm
40.6 x 25.4 x 0.95 cm
40.6 x 25.4 x 1.3 cm
3.7 m²