1. Application range
This specification is applied to ML-024D chassis.
2. Requirement for Test
Testing for standard of each part must be followed in below
condition.
(1) Temperature: 25°C ± 5°C(But, CST must be tested 40°C ±
2°C (Humidity: 50%))
(2) Humidity: 65% ± 10%
(3) Power: Standard input voltage (AC 100-220V, 50/60Hz)
(4) Measurement must be performed after heat-run more than
15min.
(5) Adjusting standard for this chassis is followed a special
standard.
4.General Specification
No.
1
Receivable broadcasting system
2
RF input channel
3
Input voltage
4
Tuning system
5
Operating temperature
6
Operating humidity
7
Storage temperature
8
Storage humidity

SPECIFICATION

Item
1)PAL/SECAM-BG
2)PAL/SECAM-DK
3)PAL-I/I
4)SECAM-L/L'
5)NTSC -M
6)NTSC 4.43(AV)
7)PAL N/M
8)NTSC-M
VHF: E02 ~ E12
UHF : E21 ~ E69
CATV : S1 ~ S20
HYPER : S21 ~ S41
L/L' : B,C,D
VHF : 2 ~13
UHF : 14 ~ 69
CATV : 1 ~ 125
VHF low : 1~M10
VHF high : 4~S22
UHF : S23~62
AC 100 - 220V ± 10%, 50/60Hz
FVS 100 program
FS
3. Test and Inspection method
(1) Capacity: Follow LG electronics TV Testing Standard.
(2) Another Required Standard
Follow the standard of each nation.
Specification
Min
Typ
0
20
-20
5
Max
Unit
50
deg
90
%
60
deg
90
%
Remark
EU/Non-EU
(PAL Market)
NTSC Market
PAL
FRANCE
NTSC
JAPAN
PAL, 200PR.(option)
NTSC