8.3.
Heating Mode Operation(Only for PA7DKD,PA9DKD)
When selecting the Heating Mode Operation, the unit will operate according to the setting by the Remote Controller and
the operation is as the following.
Time Delay Safety Control
If the compressor stopped by switching off, turning off by remote controller, or power off, it will not restart within 3 minutes.
When room temperature reaches the set temperature on the remote controller, compressor stops and will not restart within
4 minutes.
3 minutes after the compressor stopped, indoor fan will stop for 1 minute. Then indoor fan will resume operation with the
speed at "super low"
Over Load protection Control
When temperature of indoor heat exchanger rises to 51 , outdoor fan will stop
when temperature of indoor heat exchanger falls to 49 , outdoor fan will restart.
When temperature of indoor heat exchanger rises to 65
Indoor Heat Exchanger
Anti-reversing Control
If the compressor has been continuously running for 5 minutes or longer, and the difference of temperature between
intake air and evaporator is continuously lower than 5.0
restart 3 minutes later.(Time Delay Protection Control is effective.)
Compressor runs
T 5
last for 2 min
T= intake air temperature - evaporator temperature
4-way valve control
During heating mode operation,4-way valve is at
During heating mode operation,if the unit turned off, the 4-way valve will remain
at
open mode for 5 minutes.
Warm Booting Control
When turning on the unit by heating mode operation,indoor fan
will be activated when temperature of indoor heat exchanger
reaches 30 . (See the figure on the right)
Warm boot operation ends when temperature of indoor heat
exchanger reaches 34 .
.
65
5 min
or above, compressor stops, and will restart 4 minutes later.
Compressor
Stops
or below for 2 minutes, the compressor will stop , and then
Compressor
Stops
open mode.
Indoor Heat
Indoor Heat
Exchanger
Exchanger
18
Compressor Restarts
4 minutes later
Compressor Restarts
3 minutes later
Low
( )
( )
34
Super Low
Super Low
30
Indoor Fan
Indoor Fan
Stop
Stop