Heatilator BIR50-B Installation Manual page 16

Woodburning fireplace
Hide thumbs Also See for BIR50-B:
Table of Contents

Advertisement

Determine the chimney components needed to complete
your particular installation:
Measure the total vertical height of the fireplace
installation from the base of the fi replace assembly to
the approximate location of the bottom of the termination
cap.
Subtract the effective height of the fi replace assembly
(see Figure 4.1) from the total vertical height to determine
the overall height of the chimney installation.
Create a schematic for your application similar to Figure
4.1 showing components required (referring to Table 4.1).
Install a ceiling fi restop whenever the chimney penetrates
a fl oor/ceiling.
NOTICE:
A maximum of two offset and return may be
used.
CAUTION! Risk of Fire and/or Asphyxiation! DO
NOT connect this fi replace to a chimney fl ue servicing
another appliance. Do NOT connect to any air distribu-
tion duct or system. These actions could cause over-
heating/fi re in the chimney fl ue, or release of exhaust
fumes into the living areas.
16
Heatilator • Birmingham BIR50-B Installation Manual • 4059-701 • Rev B • 2/6/13
Termination
Cap
Storm
Collar
Chase Top
Flashing
74 1/8 in.
(1883 mm)
Effective
Height
Figure 4.1
(4) Roof
Radiation
Shields
Chimney Section
Attic Insulation
Shield & Collar
Square Frame
Firestop
Chimney Section
Square Frame
Firestop
Chimney Section