Case Front Controls; 83% Procedure - Lincoln Electric LN-15 WIRE FEEDER IM910 Operator's Manual

Wire feeder
Table of Contents

Advertisement

B-3

CASE FRONT CONTROLS

ACROSS THE ARC MODEL
1. WIRE FEED SPEED DISPLAY-The Wire Feed Speed
display shows the rate the LN-15 will feed electrode dur-
ing welding. The default WFS units for domestic models
are inches/minute and can be changed to meters/minute
through the configuration menu. The default WFS units
for the European models are m/min. The wire feed
speed is calibrated to within ±2%.
-
2. VOLTAGE DISPLAY
average arc voltage during the welding. A minus sign "-"
appears when welding with electrode negative welding
procedures. While welding, an LED will illuminate below
the voltage display. After welding, the average voltage
will continue to be shown for 5 seconds after the end and
the LED will flash. of the weld. When not welding, the
display shows "- - - ". The voltage is calibrated to ±2%
over a range of 10 to 45 volts.
The voltage display is not a "preset" voltage.
Refer to the examples from Figure B.1a.
3. WIRE FEED SPEED KNOB
knob is a 3-3/4 turn potentiometer that adjusts of the rate
of feeding electrode. The wire feed speed range is 50 -
700 inches/min (1.3 - 17.8 m/min)
FIGURE B.1a
OPERATION
(See Figure B.1)
The voltage display shows the
-
The Wire Feed Speed
LN-15 CONTROL CABLE MODEL (CE)
4. VOLTAGE KNOB-The voltage knob is present only on
control cable models.
Adjusting the voltage knob varies the power source volt-
age to the LN-15. The value displayed is not a "preset"
voltage. Only actual average arc voltage is shown on the
voltage display.
For codes 10864, 10865:
The voltage knob controls the output of the power source
through a 3-3/4 turn, 10K ohm potentiometer.
For codes 11033 and above:
The voltage knob controls the output of the power source
through a _ turn, 10K ohm potentiometer.
5. TRIGGER CONNECTOR-5 Pin Receptacle is used to
activate the Magnum Gun Switch.
6. CONNECTOR BUSHING-This connection is for weld-
ing conductor cable assembly.
7. ON / OFF SWITCH-For codes 11033 and above:
The ON / OFF Switch turns power on and off to the wire
feeder.

83% PROCEDURE

The LN-15 supports a special "dual procedure" mode.
When activated, the wire feed speed is reduced to
83% of the set value, but no less than 50 inch-
es/minute (1.27 m/min). The 83% procedure is most
commonly used during pipe and out of position weld-
ing. Requires Magnum 400 Dual Procedure Gun
Equivalent.
FIGURE B.1
1
3
7
5
B-3
2
4
6