Generator Troubleshooting - Coleman CM04101 Manual

Table of Contents

Advertisement

(V) STOPPING THE ENGINE
1. Before stopping engine, turn off electrical device being
2. Turn the engine switch to "STOP", see Picture 15.
3. Turn the fuel petcock to "OFF", see
picture 16.
(Picture 16)
powered and unplug it from
the generator. See Picture
14.
-12-
z Generator Troubleshooting
Problem
Possible Cause
Tripped circuit breaker
Poor connection or faulty
Indicator light ON
lead
No AC output
Broken receptacle
Faulty circuit breaker
Indicator light OFF
Generator problem
No AC output
Tripped circuit breaker
Indicator light OFF
Poor connection or faulty
No DC out put
DC power cord
Generator problem
Engine RPM set too high
or low
Output power
available
Loose component
abnormality exists
Internal generator
problem
DC APPLICATION:
The DC terminals of the generator
may be used for charging 12-volt automotive batteries only.
Connect the charging cables to the
terminals of the generator as shown.
Be sure to observe the correct polarity!
Corrective Action
Reset
Check and repair
Check and repair
Check and repair
Check and repair
Reset
Check and repair
Consult dealer
No load for 60HZ
Set 3780rpm
Locate and tighten
Consult dealer
-17-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents