7. Temperature Indication
Digital Readout; -50C - +400C in O.10C step, (200F - 1000F in O.20F step)
Graph
; plotted in the interval of +50C(+100F). When the temperature rises above
or falls below the limits of the scale, the graph is shifted to the center of
the scale.
8. Marker & Digital Readout
Marker ; Minute marker, VRM marker
Readout ; Net depth, temperature
(L/L data & time is displayed when connected with nay, system.)
9. Input/output Data*(CIF or NMEA Format)
Input
; Ship's position (L/L), ship's speed, ship's bearing, time
Output ; Net depth, temperature (CIF only)
* Optional EIS interface kit is required.
10. Output for external display/recorder unit
1) Echo Signal (upward/downward)
2) Net depth (Synchronous signal "KP" is necessary to input.)
Optional E/S interface kit (OPO1-5) is required. Echo Signal can be connected to the
color video sounder/recorder which have monitor channel.
11. Picture Record/Playback
Picture Recorder MT-12 (Optional MT-12 interface kit is required when connecting with
MT-12.)
12. Power Supply and Consumption
10-40 VDC, less than 100 W
100/110/115/200/230 VAC, 50-60 Hz, 1•
(optional rectifier RU-3423 is required.)
PARAVANE RECEIVER ND-85XX
1. Frequency and Beamwidth
2. Transducer Tilt Angle
Frequency
33 kHz
40 kHz
50 kHz
Adjustable to 15
Beamwidth
34 degrees (-3dB)
30 degrees (-3dB)
28 degrees (-3dB)
o
o
o
, 25
or 35
below horizontal
SPC-2