472. Press the
key once to change the blinking por-
tion to 11FE.
Remote commander LCD display
023 11FE00
00 : Adjusted value
473. Press the x /CHG key.
(00 is blinking)
[VOLUME +]
474. Adjust with the
[VOLUME --]
key (adjusted value down) so that the adjusted
value becomes B0.
Remote commander LCD display
023 11FEB0
B0 : Adjusted value
475. Press the X key.
(11FE is blinking)
[VOLUME +]
476. Press the
key once to change the blinking por-
tion to 11FF.
Remote commander LCD display
023 11FF00
00 : Adjusted value
477. Press the x /CHG key.
(00 is blinking)
[VOLUME +]
478. Adjust with the
[VOLUME --]
key (adjusted value down) so that the adjusted
value becomes E1.
Remote commander LCD display
023 11FFE1
E1 : Adjusted value
479. Press the X key.
(11FF is blinking)
[VOLUME +]
480. Press the
key once to change the blinking por-
tion to 1200.
Remote commander LCD display
023 120000
00 : Adjusted value
481. Press the x /CHG key.
(00 is blinking)
[VOLUME +]
482. Adjust with the
[VOLUME --]
key (adjusted value down) so that the adjusted
value becomes 78.
Remote commander LCD display
023 120078
78 : Adjusted value
483. Press the X key.
(1200 is blinking)
[VOLUME +]
484. Press the
key once to change the blinking por-
tion to 1201.
Remote commander LCD display
023 120100
00 : Adjusted value
485. Press the x /CHG key.
(00 is blinking)
key (adjusted value up) or
key (adjusted value up) or
key (adjusted value up) or
[VOLUME +]
486. Adjust with the
[VOLUME --]
key (adjusted value down) so that the adjusted
value becomes 01.
Remote commander LCD display
023 120101
01 : Adjusted value
487. Press the X key.
(1201 is blinking)
[VOLUME +]
488. Press the
key twice to change the blinking por-
tion to 1203.
Remote commander LCD display
023 120300
00 : Adjusted value
489. Press the x /CHG key.
(00 is blinking)
[VOLUME +]
490. Adjust with the
[VOLUME --]
key (adjusted value down) so that the adjusted
value becomes 02.
Remote commander LCD display
023 120302
02 : Adjusted value
491. Press the X key.
(1203 is blinking)
[DISPLAY]
492. Press the
key on the remote commander for sev-
eral seconds (about 3 seconds) to exit the patch data write
mode and display as below.
Remote commander LCD display
023 Patch09
09 : Adjusted value
493. Press the X key to write the modified data.
494. The modified data writing is over, if the adjusted value
changes to DD.
Remote commander LCD display
023 ***SDD
DD : Adjusted value
495. Turn the power off.