SAFETy INFORMATION
Continued
1. This appliance is only for use with the type of
gas indicated on the rating plate. This appliance
is not convertible for use with other gases.
2. Do not place propane/LP supply tank(s) in-
side any structure. Locate propane/LP supply
tank(s) outdoors.
3. If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not use
any phone in your building
• immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions
• if you cannot reach your gas supplier, call
the fire department
4. This heater shall not be installed in a bedroom or
bathroom, unless installed as a vented appliance.
5. Before installing in a solid fuel burning fire-
place, the chimney flue and firebox must be
cleaned of soot, creosote, ashes and loose paint
by a qualified chimney cleaner. Creosote will
ignite if highly heated. A dirty chimney flue
may create and distribute soot within the house.
Inspect chimney flue and firebox for damage. If
damaged, repair flue before operating heater.
6. Do not burn solid-fuel in a masonry or UL127
factory-built fireplace in which a vent-free
room heater is installed.
7. If fireplace has glass doors, never operate this
heater with glass doors closed. If you operate
heater with doors closed, heat buildup inside
fireplace will cause glass to burst. Make sure there
are no obstructions across openings of fireplace.
8. To prevent the creation of soot, follow the
instructions in Cleaning and Maintenance,
page 19.
9. Before using furniture polish, wax, carpet
cleaner or similar products, turn heater off. If
heated, the vapors from these products may
create a white powder residue within burner
box or on adjacent walls and furniture.
10. This heater needs fresh, outside air ventilation to
run properly. This heater has an Oxygen Deple-
tion Sensing (ODS) safety shutoff system. The
ODS shuts down the heater if enough fresh air
is not available. See Air for Combustion and
Ventilation, page 5. If heater keeps shutting off,
see Troubleshooting, page 20.
4
11. Do not run heater
• where flammable liquids or vapors are used
or stored
• under dusty conditions
12. Do not use this heater to cook food or burn
paper or any other type of solid fuels.
13. Do not use heater if any part has been exposed
to or under water. Immediately call a qualified
service technician to inspect the room heater
and to replace any part of the control system and
any gas control which has been under water.
14. Do not operate heater if any log is broken. Do
not operate heater if a log is chipped (dime-
sized or larger).
15. Turn heater off and let cool before servicing,
installing or repairing. Only a qualified ser-
vice person should install, service or repair
heater.
16. Operating heater above elevations of 4,500
feet may cause pilot outage.
17. To prevent performance problems with pro-
pane/LP models, do not use propane/LP fuel
tank of less than 100 lb. capacity.
18. Provide adequate clearances around air
openings.
Install and use heater with care. Follow all local
codes. In the absence of local codes, use the lat-
est edition of The National Fuel Gas Code ANSI
Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
National Fire Protection Association, Inc.
Note: Where listed vented decorative logs are
required, thermostat operation is not permitted.
State of Massachusetts: The installa-
tion must be made by a licensed plumber
or gas fitter in the Commonwealth of
Massachusetts.
Sellers of unvented propane or natural
gas-fired supplemental room heaters shall
provide to each purchaser a copy of 527
CMR 30 upon sale of the unit.
Vent-free gas products are prohibited for
bedroom and bathroom installation in the
Commonwealth of Massachusetts.
www.desatech.com

LOCAL CODES

1430 Broadway
New York, NY 10018
Batterymarch Park
Quincy, MA 02269
113183-01F