Solid state disk indicators
Figure 11: Indicators on the SSD modules
1 LED
BUSY (green)
green
– Lights up: SSD in active phase
– Does not light: SSD inactive (drive inactive)
2 LED
FAULT (orange)
orange
(in conjunction with a RAID controller)
– Does not light: no error
– Lights up: Faulty or Rebuild Stopped (drive defective/needs
replacing, a rebuild process was stopped or the module is not
correctly inserted)
– Slow flashing: Rebuild (the data is being restored after
changing a drive)
– Fast flashing: Identify
– Four fast blinks/pause: Predicted Fault
– Two fast flashes/pause: Hot Spare (Hot spare drive active. The
corresponding drive has failed).