NOTE: The appliance and its individual shutoff valve must be disconnected from the gas
supply piping system during any pressure testing of the system at test pressures in excess of
1/2 psi (3.5 kPa).
The appliance must be isolated from the gas supply piping system by closing its individual
manual shutoff valve during any
at test pressures equal to or less than 1/2 psi (3.5kPa).
An 1/8" NPT plugged tap is located on the right side of the regulator, immediately upstream
of the gas supply connection to the appliance. This is used for test gauge connection.
NOTE: Your heater is equipped with a piezo ignitor.
Read 1 - 7 before lighting the unit for the first time.
1. Open the cover door.
2. Turn the regulator valve to "PILOT", push it in and hold.
3. Press the igniter button. If the line is bled out, the pilot will generally light with two-three
pushes on the igniter.
4. Hold the pilot in for approximately one minute.
5. Release the pilot valve and the flame should stay lit. NOTE: If pilot fails to stay lit, wait
five minutes and repeat steps 2 through 5. If this continues, consult the trouble
shooting guide.
6. Turn the regulator valve to the "ON" position.
7. Flip the "ON/OFF" switch to the "ON" position, (the red is exposed).
8. If you wish to turn the burner off, flip the "ON/OFF" switch. If a wall switch has been
installed, simply turn it off. NOTE: The pilot will stay lit.
9. To turn off the pilot, push in and turn the valve to the "OFF" position.
NOTE: When the unit is initially lit, condensation will appear on the glass. This is normal in
all gas fireplaces, and will disappear in one to three minutes.
NOTE: A paint smell will occur during the first few hours of burning. It is recommended
to leave the fan off during this period. This will speed up the paint curing process.
NOTE: CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF
HIGH SURFACE TEMPERATURE AND SHOULD STAY AWAY TO AVOID BURNS
OR CLOTHING IGNITION.
SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.
CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED
ON OR NEAR THE APPLIANCE.
pressure
testing of the gas supply piping system
YOUNG CHILDREN SHOULD BE CAREFULLY
9