Select Readouts (Advanced, Sonar View Only); Depth Offset (Advanced); Temp Offset - Humminbird 343c Operation Manual

300 series
Hide thumbs Also See for 343c:
Table of Contents

Advertisement

531447-1_A_343c_Eng.qxd
11/11/2005
Select Readouts
(Advanced, Sonar view only)
Select Readouts sets individual digital readouts on the Sonar View. This Advanced
feature allows you to select what data will be displayed in each of 5 fixed-position
data windows arranged around the left and bottom edges of the Sonar View
screen, or whether a particular window will be turned off, displaying nothing in
that area; you can access this menu choice only when in Advanced User Mode
(see Setup Menu Tab: User Mode.)
Data windows can display readouts from
supported accessories such as Temp/Speed. Each
data window can either be empty or contain one of
the following:
- Speed (will be displayed if a Temp/Speed
Accessory is attached and the paddlewheel has
moved at least once)
- Temperature
- Triplog (will be displayed if a Temp/Speed
Accessory is attached and the paddlewheel has
moved at least once)
Select Readouts
- Voltage.
www.Busse-Yachtshop.de
email: info@busse-yachtshop.de
9:18 PM
Page 54
49
Depth Offset
(Advanced)
Depth Offset will adjust the digital depth readout to indicate depth from the waterline
or boat's keel. Enter a positive vertical measurement from the transducer to the
waterline to read the depth from the waterline. Enter a negative vertical measurement
from the transducer to keel to read the depth from the keel. This menu choice is
available only when in Advanced User Mode (see Setup Menu Tab: User Mode.)
To change the Depth Offset setting:
1. Make sure you are in Advanced User Mode, then highlight Depth Offset on the Setup
menu.
2. Use the LEFT or RIGHT 4-WAY Cursor Control keys to change the Depth Offset setting.
(-10.0 to +10.0 feet or -3 to 3 meters [International Models Only], Default = 0)

Temp Offset

(Advanced)
Temp Offset will adjust the temperature readout by the amount entered. This menu
choice is available only when in Advanced User Mode (see Setup Menu Tab: User Mode.)
To change the Temp Offset setting:
1. Make sure you are in Advanced User Mode, then highlight Temp Offset on
the Setup menu.
2. Use the LEFT or RIGHT 4-WAY Cursor Control keys to change the Temp Offset
setting. (-10.0 to +10.0 degrees, Default = 0)