Mitsubishi Electric MS-A•WA Service Technical Manual page 25

Split-type, air conditioners split-type, heat pump air conditioners
Hide thumbs Also See for MS-A•WA:
Table of Contents

Advertisement

<Correction>
1 Discharge temperature
2 Each correction
• (Each gas pipe temperature thermistor - Minimum gas pipe temperature thermistor)w 1
• (Main indoor coil thermistor - Sub indoor coil thermistor)
w 1 Perform this, when number of operation units is 2 units or more.
w 2 Correct the LEV opening by discharge temperature.
(1) LEV opening correction by discharge temperature
The target discharge temperature is determined according to frequency zone and number of operation unit of the
compressor.
MXZ-2A
Operation frequency
of compressor (Hz)
Minimum ~ 23
24 ~ 38
39 ~ 54
55 ~ 69
70 ~ 85
86 ~ Maximum
MXZ-3A
Operation frequency
of compressor (Hz)
Minimum ~ 14
15 ~ 23
24 ~ 32
33 ~ 41
42 ~ 50
51 ~ 59
60 ~ 68
69 ~ 77
78 ~ 86
87 ~ Maximum
Target discharge temperature (˚F)
COOL
Number of operating unit
2 units
1 unit
136.4
95
104
120.2
154.4
136.4
149
158
Target discharge temperature (˚F)
COOL
Number of operating unit
1 unit
2 units
95
131
104
131
120.2
136.4
136.4
140
149
149
154.4
154.4
158
158
167
163.4
167
167
167
176
Number of operating unit
1 unit
122
140
132.8
149
140
140
158
140
158
140
Number of operating unit
3 units
1 unit
134.6
125.6
134.6
136.4
145.4
149
149
154.4
158
154.4
163.4
154.4
167
154.4
176
154.4
179.6
154.4
179.6
172.4
25
COOL
DRY
HEAT
w 2
w 2
-
HEAT
2 units
122
122
132.8
140
140
140
HEAT
2 unit
3 units
143.6
122
150.8
131
165.2
140
172.4
152.6
172.4
161.6
172.4
168.8
172.4
168.8
172.4
168.8
168.8
172.4
172.4
168.8