Mitsubishi Electric PAR-SL94B-E User Instructions page 7

Wireless remote controller kit for ceiling suspended m

Advertisement

Wireless Remote Controller Kit
Self-Check
6
Turn on the main power to the unit.
CHECK
Press the
button twice continuously.
(Start this operation from the status of remote controller display turned off.)
begins to light.
CHECK
«00» begins to blink.
While pointing the remote controller toward the unit's receiver, press
h
the
button. The check code will be indicated by the number of
times that the buzzer sounds from the receiver section and the number
of blinks of the operation lamp.
Press the ON/OFF button to stop the self-check.
Refer to the following tables for details on the check codes.
Output pattern (Mr.Slim model / CITY MULTI model)
[Output pattern A]
Beeper sounds
Beep
Beep Beep Beep
OPERATION
st
1
INDICATOR
lamp blink
Off
On
pattern
Approx. 2.5 sec.
0.5 sec.
Self-check
starts
(Start signal
Number of blinks/beeps in pattern indicates the check
received)
code in the following table (i.e., n=5 for "P5")
[Output pattern B]
Beeper sounds
Beep
OPERATION
INDICATOR
lamp blink
Off
pattern
Approx. 2.5 sec.
Approx. 3 sec.
Self-check
starts
(Start signal
received)
Check code (Mr.Slim model)
[Output pattern A] Errors detected by indoor unit
Wireless remote controller Wired remote
controller
Beeper sounds/OPERATION
INDICATOR lamp blinks
Check code
(Number of times)
1
2
P2, P9
3
E6,E7
4
5
6
7
8
9
10
11
12
No sound
for Ceiling Suspended models
Beep
Beep Beep
nd
rd
th
2
3
n
1
On
On
Off
On
On
0.5 sec.
0.5 sec.
Approx. 2.5 sec.
0.5 sec.
0.5 sec.
Number of blinks/beeps in pattern indicates
the check code in the following table
Beep Beep Beep
Beep
st
nd
rd
1
2
3
n
On
On
On
On
On
0.5 sec.
0.5 sec.
0.5 sec.
0.5 sec.
Number of blinks/beeps in pattern indicates the check
code in the following table (i.e., n=5 for "U2")
P1
Intake sensor error
Pipe (Liquid or 2-phase pipe) sensor error
Indoor/outdoor unit communication error
P4
Drain sensor error/Float switch connector open
Drain pump error
P5
P6
Freezing/Overheating safeguard operation
Communication error between indoor and outdoor units
EE
Pipe temperature error
P8
Remote controller signal receiving error
E4
Indoor unit control system error (memory error, etc.)
Fb
– –
No corresponding
PAR-SL94B-E
CHECK
ON/OFF
MODE
CHECK
LOUVER
TEST RUN
SET
RESET
st
nd
· · · Repeated
2
On
0.5 sec.
Beep
th
1
st
Off
On
On
Approx. 2.5 sec.
Approx. 3 sec.
0.5 sec.
Number of blinks/beeps in pattern indicates
the check code in the following table
Symptom
TEMP
FAN
AUTO STOP
VANE
AUTO START
h
min
CLOCK
Beep
2
nd
· · · Repeated
On
0.5 sec.
Remark
E-135