After the refrigerator has been connected, all accessible connectons
should be checked for soundness by applying a soap/water solution
over them and watching for bubbles with, of course, the bas-bottle
and any gas cocks in the line, turned on. DO NOT USE A FLAME.
Thereafter, all connections should be checked periodically, in the
same way, to ensure that they have not loosened in use.
Car
Optional Relay
(see also fig. 12b)
15 amp. fuse
Main 12V battery in car
14. INTRODUCTION
To ensure satisfactory operation, it is essential that the refrigerator is
installed and used as directed in this instruction booklet. The
ventilation openings above and below the refrigerator must not be
reduced in size or obstructed in any way otherwise the performance
of the cooling unit may be impaired.
8
2
2 mm
(minimum) wire
Type 12S (Supplementary) 7 pin
plug and socket
FIG. 12a 12V WIRING ARRANGEMENT
Battery
Fuse
Ignition Controlled
Feed
DIAGRAM SHOWING AN IGNITION CONTROLLED RELAY
IN THE WIRING TO THE REFRIGERATOR

INSTRUCTIONS FOR USE

Two cores (red for the supply, white for the
common return) of 7-core 'ISO 4141' flexible
cable
Two 2 mm
Switch or plug
and socket
Fig. 12a
RELAY
Fig. 12b
Fig. 13
Levelling
When the refrigerator is operating, liquid refrigerant trickles
theough the pipework of the cooling unit under the influence of
gravity. To enable a satisfactory flow to take place, the unit must
be reasonably level, from side to side and from front to back,
otherwise refrigerant can accumulate in pockets instead of
flowing back to the bottom, and the cooling process may be
impaired or cease.
Caravan
2
(minimum) wires
Terminal block on back of
refrigerator. (Leave sufficient
slack wire for refrigerator to
be withdrawn).
Supply to
Refrigerator
Travel catch
Ice-tray
Drip collector
Flame control tube
Gas controls

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rm 122f

Table of Contents