Download Print this page

Whirlpool RH2300 series Installation Instructions And Use And Care Manual page 5

24", 30", 36" custom series range hood

Advertisement

9
n
Install duct throuah
the vent
opening
in upper
cabinet
or wall.
Complete
venting
system according
to
method
needed.
See "Venting
requirements."
Use caulking
to seal exterior
wall or roof opening.
10V
W If roof or wall cap does not
Numbers
corresoond
to steyjs.
To install a non-vented
have a damper, attach rectangular
damper
supplied with hood
to selected
rectangular
vent opening.
If damper
is attached
to
back of range hood, be sure damper
hinge
is toward
the top.
If roof or wall
cap
does not have a damper
and round duct is used,
install damper
(supplied
with hood)
in duct to prevent
air
from flowing
back into duct.
If roof or wall cap has a damper,
Do not
use damper
blade
supplied
with range
hood.
(recirculating-only)
model:
-
3a
H Remove
knockout
from the
wiring opening
(rear or top) to be used.
The range hood cabinet
may have venting
knockouts.
Do not remove these venting
knockouts.
The model
cannot
be vented.
I
I
from wall,
I
(not
I
cabinet
I
frame)
11
n
Run wirina throuah
wall or
cabinets
according
t&-the N%ional
Electrical
Code
and local codes
and
ordinances.
Do not turn on power until
installation is complete.
Use caulking
to seal
ceiling
or outside
wall opening.
centerline
terminal
box
7a
~TO wire through top,
mark a line
7-l /2" from the riaht of the centerline
on
the underside
ofThe cabinet.
Mark the
point on this line that is l-3/8" from the back
wall. Drill a l-l /4" diameter
hole through
cabinet
at this point.
keyhole
slot
Check
that screw is in
narrow
neck of slot.
front of hood
12
m
screw
H Start screws in the center
of
the narrow
neck of each
of the four
keyhole
mounting
screw slots marked
on
the cabinet
bottom.
H Remove terminal
box cover
I
I
0
di
J
.___.-,-.-.
"r
5
I,
1-W
! 7-lfl'
&I-5/8"
I
00
floor)
i
I
4
\I,
I
on
13
W Lift range
hood into final
range hood.
position, feeding
electrical
wire through
wiring opening.
Tighten
mounting
screws to
cabinet,
making
sure mounting
screws are
in narrow
neck of slots.
Excessive Weight Hazard
Use two or more people to move and
install range hood.
Failure to follow this instruction
can
result in back or other injury.
+
I
centerline
To wire through rear,
mark a line 7-l /2" from
the right of the centerline
on the wall. Mark
the point on this line that is &l-5/8"
from the
floor (or l-3/8" from underside
of cabinet).
Drill a l-l /4" diameter
hole through
wall at
this point.
front oi hood
keyhole
slot
Sa
W Lift range hood into final
Electrical Shock Hazard
Disconnect power before making
electrical connections.
Connect ground wire to green ground
screw in terminal box.
Failure to do so can result in death or
electrical shock.
8a
n
Run wirina throuah
wall or
cabinets
according
to' the N$ional
Electrical
Code
and local codes
and
ordinances.
Do not turn on power until
installation is complete.
Use caulking
to
seal ceiling or outside wall opening.
position
and center. Mark on underside
of
cabinet
the location
for the four keyhole
mounting
slots. Set range hood aside on a
protected
surface.
keyhole
slot
front of hood
Check
that screw is in
narrow
neck of slot.
9a
m
screw
H Start screws in the center
of the
narrow
neck of each
of the four keyhole
mounting
screw slots marked
on the
cabinet
bottom.
1
I Connect
the white and black
wires of the power supply cable
to the
white and black leads in the range
hood
with twist-on
connectors.
Connect
the power
supply ground
wire to
the green ground
screw inside the range
hood terminal
box.
Use caulking
to seal wire opening.
Replace
terminal
box cover.
IOa
W Lift range hood
into final
centerline
6a
n
Determine
and clearly
mark a
position,
feeding
electric%1 wire through
wiring opening.
Tighten
mounting
screws to
cabinet,
making
sure mounting
screws are
in narrow
neck of slots.
vertical
centerline
in the cabinet
opening.
Panel D

Advertisement

loading

This manual is also suitable for:

Rh2000 seriesRh2600 series