Overall Dimensions; Clearances - Ariston microCombi 23 MFFI Installation And Servicing Instructions

Type c boilers g.c.n: 47-116-16 (23kw) g.c.n: 47-116-24 (27kw)
Hide thumbs Also See for microCombi 23 MFFI:
Table of Contents

Advertisement

F
. 2.1
IG
F
. 2.2
IG
6
within a cupboard.
This appliance is not suitable for outdoor installation.
The type C appliances (in which the combustion
circuit, air vent intake and combustion chamber are
air-tight with respect to the room in which the
appliance is installed) can be installed in any type of
room.
Secondary ventilation is not required with this boiler. The
boiler must be installed on a solid, non-combustible,
permanent wall to prevent access from the rear.
2.3
O
VERALL
L
:
EGEND
A = Central Heating Flow (3/4")
B = Domestic Hot Water Outlet (1/2")
C = Gas Inlet (3/4")
D = Domestic Cold Water Inlet (1/2")
E = Central Heating Return (3/4")
QT002A
2.4
C
LEARANCES
In order to allow access to the interior of the boiler for
maintenance purposes, the boiler must be installed in
compliance with the minimum clearances indicated in F
2.2
DM001B
D
IMENSIONS
.
IG