OPERATION DISTURBANCES

4.1.
THE MOST USUAL OPERATION DISTURBANCES ARE
AS FOLLOWS:
Arc is not ignited:
-
Cable is loose or there is a bad connection.
-
Electrode of torch is highly oxidized (grey). Sharpen again lengthwise. Check that
post gas time is long enough. Check ignition by using pre-gas e.g. by 4-function
operation of torch.
-
There are impurities in shielding gas (moisture, air).
-
Protective hose or another insulation of torch is broken and ignition spark is "esca-
ping" from elsewhere than from electrode of torch.
-
Torch is wet.
-
At low current is used too big or blunt electrode.
Gas shielding is bad (weld pool "is boiling", electrode will be oxidized)
-
There are impurities in shielding gas (moisture, air).
-
There are impurities in base material (rust, base coat, grease).
-
On gas nozzle or housing of tightening bushing has stuck "spatter".
-
Net of gas lens is damaged.
-
There is too much draught at welding place.
-
Note! With gas lens equipment you get a more balanced gas flow than with normal
gas nozzle equipment.
5.

ORDERING NUMBERS

TTC 130
4m
627013004
8m
627013008
16m
627013016
TTC 220
4m
627022004
8m
627022008
16m
627022016
10 – TTC 130, TTC 130F, TTC 160, TTC 160S, TTC 220, TTC 200W,
TTC 250W, TTC 250WS/0109
TTC 130F
TTC 160
627013104
627016004
627013108
627016008
627013116
627016016
TTC 200W
TTC 250W
627020504
627025504
627020508
627025508
627020516
627025516
TTC 160S
627016204
627016208
627016216
TTC 250WS
627025704
627025708
627025716
©
COPYRIGHT KEMPPI OY

Advertisement

Table of Contents
loading

Table of Contents