c. Minimum dimensions of ventilation gaps
Induction hob over an oven
less than 35 mm
Ceramic glass
more than 15mm
10mm
Air out
Built-in oven
Air in
d. Connection of the appliance to the supply mains
The connection between the plug and the appliance should use the power cord provided by the manufacturer,
which should not be longer than 1.5m. If the socket is not accessible after installation, an additional means of
disconnection must be provided for all poles
The PCB is made in Germany, which complies with:
IEC 60335-2-6 : 2002 IEC 60335-2-9 : 2002
(in conjunction with IEC 60335-1 : 2001)
Note: If the power cord is damaged, it must be replaced by the manufacturer or its service department or similar
professional in order to avoid the dangerous.
Special point to note on installation
Please do not disassemble the screws fixed on the sides on the top of the ventilation point of the induction cooker.
These two screws are fixed to ensure a gap of 10mm is kept between the induction cooker and the kitchen cabinet,
guaranteeing the induction cooker to have a good ventilation. The manufacturer is not responsible for any faults
and problems caused by unauthorised disassembling.
PCB board
Table Top
at least 100mm
Wall
at least 40mm
Induction hob over an drawer
less than 35 mm
Ceramic glass
more than 15mm
10mm
Air out
Air in
5
PCB board
Table Top
at least 100mm
Wall
at least 40mm