OPERATING PROCEDURE
3. Removing the compressor
(1) Remove the lead clamps.
(2) Remove the screws fixing the relay panel.
(3) Remove the screw fixing the service port.
(4) Remove the terminal cover.
(5) Pull out the lead from the compressor terminal.
(6) Remove the overcurrent relay.
(7) Remove the compressor nuts.
(8) Detach the suction pipe welded section and discharge pipe
welded section with a burner.
NOTE
Before using a burner, purge gas from the pipes until the pres-
sure gauge shows 0 kg/cm
Use the burner under the condition that gas can be released
even when the inner pressure rises by heat.
50
2
.
PHOTOS
Photo 4
Terminal cover
compressor
Discharge pipe
Suction pipe

Hide quick links: