Mitsubishi Electric MS-07NV -E1 (WH) Service Manual page 32

Split-type,heat pump air conditioners
Table of Contents

Advertisement

(3) Positioning
The vane is once pressed to the vane stopper below to confirm the standard position and then set to the desired angle.
The positioning is decided as follows.
(a) When the OPERATE/STOP button is pressed. (POWER ON/OFF)
(b) When the vane control is changed from AUTO to MANUAL.
(c) When the SWING is finished.
(d) When the test run starts.
(e) When the power supply turns ON.
(4) VANE AUTO (
) mode
In VANE AUTO mode, the microprocessor automatically determines the vane angle and operation to make the optimum
room-temperature distribution.
In COOL and DRY operation
In FAN operation
(5) Dew prevention
During COOL or DRY operation at Vane Angle 4 or 5 when the compressor cumulative operation time exceeds 1 hour, the
vane angle automatically changes to Angle 1 for dew prevention.
(6) SWING MODE (
)
By pressing the SWING button (
celled when the SWING button or VANE CONTROL button (
mode.
7. SLEEP MODE
(
)
• When the SLEEP button (
indoor unit is decreased.
• The indications of the remote controller are "
• When the FAN SPEED CONTROL button (
mode is released.
32
) vane swings vertically. The remote controller displays "
) is pressed, the indoor fan speed drops and the air flow sound from the
" and "
) is pressed during the SLEEP mode , the SLEEP
Vane angle is fixed to Angle 1.
Vane angle is fixed to Angle 4.
) is pressed or the operation stops or changes to other
".
". SWING mode is can-