Installation

- Install the AWT on an internal wall at a height of approx. 1.5 m.
- Install the AWT in a room, which is representative of the entire living accommodation.
- The AWT must not be subject to draughts or radiated heat.
- The AWT must not be blocked by furniture or curtains.
- In this room, all radiator valves must be fully opened.
- Lever the AWT top from its base using a
screwdriver.
In doing so, insert the screwdriver into the
lower cutout of the base, and lever the base
at the terminal strip.
- Secure the base through the fixings holes.
Remove the AWT from its base using a screwdriver
Telecontrol contact
Connection
data cable
e-BUS or
+ -
SCOM
1
2
Installation
Fixing holes
Connection
of outside
temperature
sensor
3
4
Plug to the
5
6
top part
5