IMPORTANT
The slide out room can be stopped at any time by releasing the slide out switch.
If the slide out room stops before reaching the full "OUT" or "IN" position, the
slide out controller may need adjustment. To adjust the slide out controller, turn
the adjustment screw clockwise to increase the power and counter-clockwise to
decrease the power. Move the adjustment screw in small increments. Try
moving the slide out room again. Use caution. There is a potential for
component or structural damage if the screw is adjusted too high. This screw
does not adjust the slide out room speed. It sets the amount of power required
to move the room against the mechanical stops.
IMPORTANT
On units equipped with manual lock arms, it is important to release the switch
as soon it has pulled tight and stopped moving. Current will be applied to the
slide out motor as long as you hold the switch. Automatic resetting circuit
protection is incorporated to minimize the chance of failures from not releasing
the button at the end of room travel, but timely releasing of the button before the
circuit protection engages is highly recommended.
MANUAL EXTENSION
AND RETRACTION

Shaft end-mounted motors

If the motor is mounted on the ends of the
slide out shaft, use the following
directions:
1.
Access must be gained to the
TRANS-TORQUE bushing coupling at the end of the slide out gear
motor.
2.
Using a 1/2" drive – 11/2" open end wrench and a 1/2" drive ratchet
wrench, loosen the 11/2" nut. This will require approximately 11/2 turns.
The nut is a standard right hand thread. After the initial release, the nut
will turn for a partial turn, and then will release again as you turn the
wrench. This second release is required to loosen the TRANS-TORQUE
bushing from the shaft.