i.e. in ASCII from 20H to 7EH.
Alphanumeric character only- If this option is selected, the scanner will output the alphanumeric
characters only, i.e. "A"-"Z", "a"-"z", "0"-"9".
Decoder optimization: If it is enabled, the scanner will optimize the decoder with error correction. This
function is not effective for all types of barcodes.
Data output delay in continue-scan mode: If it is enabled, in the continue-scan mode, the scanner can
store the data while continue-scanning. The scanner will output the data after the predefined delay
elapsed. The maximum storage of data is 1000 characters. If this parameter is set to be "00", the
scanner will not store data. And if the parameter is set to be "FF", the scanner will output data after
stopping scanning.
Enter sleeping-mode delay: The scanner will enter sleeping mode if the scanner has been in the idle
mode after the predefined delay elapsed. The scanner will be awakened by pressing the trigger once.