If Door Controller Orbit; Connecting With Utp Cable; Connection With Cky 3X2X0,14Mm² - Keyprocessor Sirius i80 Installation Manual

Table of Contents

Advertisement

3.3

If door controller Orbit

Recommended cable type between the Orbit and Sirius card reader:
CKY 3x2x0,14mm²
CKY 4x2x0,14mm²
CAT5 UTP four twisted pairs of 24AWG copper conductors
CAT6 UTP four twisted pairs of 24AWG copper conductors
3.3.1

Connecting with UTP cable

TIA/EIA-568-B
Cable color
White/orange
Orange
White/green
Blue
White/blue
Green
White/brown
Brown
3.3.2
Connection with CKY 3x2x0,14mm²
Cable color
Green
Yellow
Pink
Grey
White
Brown
Connection
on the Orbit
Data/D0
-
Clock/D1
+5V
LED
-
GND
GND
Connection
on the Orbit
Data/D0
Clock/D1
+5V
LED
GND
GND
Connection
Sirius i80 card reader
3
-
4
7
5
-
6
6
Connection
Sirius i80 card reader
3
4
7
5
6
6