Selection Data; Specifications - Mitsubishi SRK52HE Technical Manual

Wall mounted type room air conditioner
Table of Contents

Advertisement

2

SELECTION DATA

2.1 Specifications

Model SRK52HE (Indoor unit)
SRC52HE (Outdoor unit)
Item
(1)
Cooling capacity
Heating capacity
(1)
Power source
Cooling input
Running current (Cooling)
Heating input
Running current (Heating)
Inrush current
COP
Cooling
Noise level
Heating
Exterior dimensions
Height × Width × Depth
Color
Net weight
Refrigerant equipment
Compressor type & Q'ty
Motor
Starting method
Heat exchanger
Refrigerant control
(3)
Refrigerant
Refrigerant oil
Deice control
Air handling equipment
Fan type & Q'ty
Motor
Air flow (at High)
Air filter, Q'ty
Shock & vibration absorber
Electric heater
Operation control
Operation switch
Room temperature control
Pilot lamp
Safety equipment
O.D
Connecting method
Attached length of piping
Insulation
Drain hose
Power source supply
Size × Core number
Connection wiring
Connecting method
Accessories (included)
Optional parts
Notes (1) The data are measured at the following conditions.
Operation
Cooling
Heating
The piping length is 7.5m.
(2) The operation data are applied to the 220/230/240V districts respectively.
(3) The refrigerant quantity to be charged includes the refrigerant in 7m connecting piping.
(Purging is not required even in the short piping.)
If the piping length is longer, when it is 7 to 15m, add 25g refrigerant per meter.
Model
W
W
kW
A
kW
A
A
Sound level
Power level
dB
Sound level
Power level
mm
kg
kW
kg
R
W
(Cooling)
CMM
(Heating)
Compressor: overheat protection, Heating overload protection (High pressure control), Frost protection,
Serial signal error protection, Indoor fan motor error protection
mm (in)
Mounting kit, Clean filter (Natural enzyme filter × 1, Photocatalytic washable deodorizing filter × 1)
Item
Indoor air temperature
DB
27ºC
20ºC
SRK52HE
1 Phase, 220-240V, 50Hz
Cooling: 3.12 Heating: 3.76
Hi 43, Me 39, Lo 36
59
Hi 41, Me 39, Lo 37
59
318 × 1098 × 248
Yellowish white
15
Slit fins & inner grooved tubing
Capillary tubes + Electric expansion valve
R22 1.6 (Pre-Charged up to the piping length of 7m)
0.7 (B-32SAM)
Microcomputer control
Tangential fan × 1
46
17
18
Polypropylene net (washable) × 2
Wireless-Remote control
Microcomputer thermostat
RUN (Green), TIMER (Yellow), HI POWER (Green), ECONO (Orange)
Liquid line: φ6.35 (1/4") Gas line: φ15.88 (1/2")
Flare connecting
Liquid line: 0.70m
Gas line: 0.63m
Necessary (Both sides)
Terminal block (Screw fixing type)
× 4 cores (Including earth cable)
2
1.5 mm
Terminal block (Screw fixing type)
Wired - Remote control
Outdoor air temperature
WB
DB
19ºC
35ºC
7ºC
2
-
-
SRC52HE
5400
5600
1.73
8.6/8.3/7.9
1.49
7.4/7.1/6.8
42
49
65
49
65
640 × 850 × 290
Stucco white
47
RM5522GNE4 (Rotary type) × 1
1.7
Line starting
Straight fin & inner grooved tubing
Propeller fan × 1
43
42
42
Cushion rubber (for compressor)
Connectable
WB
24ºC
6ºC
(220/230/240V)
Standards
ISO-T1, JIS C9612
ISO-T1, JIS C9612

Advertisement

Table of Contents
loading

This manual is also suitable for:

Srk71heSrk63he

Table of Contents