Standard to which Conformity is declared: EN61010-1:2001 (Safety requirements for electrical equipment for measurement, control and laboratory use - Part 1) Manufacturer's Name and Address: KEPCO INC. 131-38 SANFORD AVENUE FLUSHING, N.Y. 11355 USA Importer's Name and Address: Type of Equipment: Rack Adapter Model No.:...
Page 3
All operator adjustments are made via externally accessible switches, controls and signal lines as specified within the individual power supply operating instructions. There are no user or operator serviceable parts within this product enclosure. Refer all servicing to qualified and trained Kepco service technicians. 228-1362 COND/CONFORM 032615...
SAFETY INSTRUCTIONS 1. Installation, Operation and Service Precautions This product is designed for use in accordance with EN 61010-1 and UL 3101 for Installation Category 2, Pollution Degree 2. Hazardous voltages are present within this product during normal operation. The prod- uct should never be operated with the cover removed unless equivalent protection of the operator from accidental contact with hazardous internal voltages is provided: There are no operator serviceable parts or adjustments within the product enclosure.
LIST OF FIGURES FIGURE TITLE PAGE Kepco Model RA 55 Rack Adapter ......................1 RA 55 Backplate Assembly......................... 2 Controller to Power Module Interface ......................3 RA 55 Interconnections and Input/Output Pin Connections................ 4 Mechanical Outline Drawing of the RA 55 Rack Adapter................5 Load Connector Assembly Procedure ......................
The rack adapter can use 18-inch (457.2 mm) Jonathan Model 110-QD-18-2 chassis slides. The rack adapter can be equipped with optional 1/9 rack blank filler panels (Kepco Model RFP 55-1) if the full complement of nine power supplies is not utilized.
Terminal G (Ground) is the safety ground connection for the RA 55. It is connected to the RA 55 chassis and to the safety ground terminal of the input power connector for each of the nine mounting positions via the PCB backplane. Terminal G must be con- RA55 032615...
MST modules installed. Operation below 100V rms can result in source current in excess of 15A at terminal block J10 or J11. For this reason Kepco rec- ommends use of #14 AWG wire (minimum) in fully populated systems. For lower system power configurations, smaller wire can be used;...
NOTE: Before installing MST Power Module in RA 55 Rack Adapter, pull out the two captive thumb screws at the front of the Power Module and turn counterclockwise until the threads engage. FIGURE 6. LOAD CONNECTOR ASSEMBLY PROCEDURE RA55 032615...