KEPCO RA 19-4C Instruction Manual

Rack adapter
Hide thumbs Also See for RA 19-4C:
Table of Contents

Advertisement

Quick Links

INSTRUCTION MANUAL
HSF 300W, 600W, 1200W, 1500W SERIES POWER SUPPLIES
KEPCO INC.
An ISO 9001 Company.
IMPORTANT NOTES:
1)
This manual is valid for the following Model and associated serial numbers:
MODEL
2)
A Change Page may be included at the end of the manual. All applicable changes and
revision number changes are documented with reference to the equipment serial num-
bers. Before using this Instruction Manual, check your equipment serial number to identify
your model. If in doubt, contact your nearest Kepco Representative, or the Kepco Docu-
mentation Office in New York, (718) 461-7000, requesting the correct revision for your par-
ticular model and serial number.
3)
The contents of this manual are protected by copyright. Reproduction of any part can be
made only with the specific written permission of Kepco, Inc.
Data subject to change without notice.
©2018, KEPCO, INC
P/N 243-1134-R5
KEPCO, INC.
131-38 SANFORD AVENUE
RA 19-4C
RACK ADAPTER
HOT SWAP RACK ADAPTER FOR
MODEL
RA 19-4C
RACK ADAPTER
ORDER NO.
SERIAL NO.
FLUSHING, NY. 11355 U.S.A.
email: hq@kepcopower.com
REV. NO.
REV. NO.
KEPCO
THE POWER SUPPLIER™
TEL (718) 461-7000
World Wide Web: http://www.kepcopower.com
®
FAX (718) 767-1102

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RA 19-4C and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for KEPCO RA 19-4C

  • Page 1 Before using this Instruction Manual, check your equipment serial number to identify your model. If in doubt, contact your nearest Kepco Representative, or the Kepco Docu- mentation Office in New York, (718) 461-7000, requesting the correct revision for your par- ticular model and serial number.
  • Page 3: Table Of Contents

    2.11.1 Safety Grounding..........................2-34 2.11.2 Source Power Connections ....................... 2-34 2.11.2.1 EMI Compliance........................... 2-35 2.11.3 Control Signal Connections ....................... 2-35 2.11.4 Output Load Connections ........................2-35 2.11.4.1 Reducing Ripple and Noise ......................2-35 2.11.4.2 Parallel/Redundant Operation...................... 2-36 RA 19-4C 120318...
  • Page 4 TABLE OF CONTENTS SECTION PAGE 2.11.4.3 Series/Independent Operation ....................2-36 2.11.4.4 Mixed Operation.......................... 2-36 2.12 Removing/Replacing HSF Power Supplies .................... 2-36 2.13 Shipping..............................2-36 RA 19-4C 120318...
  • Page 5 TITLE PAGE RA 19-4C Rack Adapter ..........................vi RA 19-4C Rack Adapter with 300W, 600W, 1200W or 1500W HSF Power Supplies Installed....1-1 RA 19-4C Rear Panel Interconnections ...................... 1-2 RA 19-4C Rack Adapter Rear Panel ......................1-3 RA 19-4C Schematic Diagram ........................1-7 RA 19-4C Mechanical Outline Dimensions ....................
  • Page 6 TITLE PAGE Compatible HSF Power Supplies ....................... 1-4 RA 19-4C Accessories ..........................1-4 Equipment Supplied ........................... 2-1 Rear Panel DIP Switch Functions ......................2-2 HSF DIP Switch Configuration for Group Control (allows Master to control Output WHILE Slaves Track Master) 2-11 HSF DIP Switch Configuration for Voltage Control of Multiple Units in Series ...........
  • Page 8 3042843 FIGURE 1-1. RA 19-4C RACK ADAPTER RA 19-4C 120318...
  • Page 9: Section 1 - Introduction

    SECTION 1 - INTRODUCTION SCOPE OF MANUAL This manual contains instructions for the installation and operation of the RA 19-4C plug-in rack adapter (Figure 1-1) used with 300W, 600W, 1200W and 1500W HSF power supplies, manufac- tured by Kepco, Inc., Flushing, New York, U.S.A.
  • Page 10: Ra 19-4C Rear Panel Interconnections

    FIGURE 1-3. RA 19-4C REAR PANEL INTERCONNECTIONS RA 19-4C 120318...
  • Page 11: Mechanical

    Mechanical dimensions, material, and finish of the RA 19-4C Rack Adapter are provided in Fig- ure 1-6. ACCESSORIES Accessories for RA 19-4C Rack Adapters are listed in Table 1-2; see also Table 2-1 for addi- tional accessories supplied with the unit. OPTIONS Table 1-1 describes the standard model options available with the RA 19-4C rack adapter.
  • Page 12: Compatible Hsf Power Supplies

    HSF 48-7 * Unless otherwise noted, Models that include a suffix specifying an option, e.g., M for Meter, C for Current Monitoring, etc., are compatible. Contact Kepco Applications Engineering for assistance with non-standard configurations. TABLE 1-2. RA 19-4C ACCESSORIES ACCESSORY...
  • Page 13 Protective cover 137-0145 terminals. Four standoffs (not supplied), Kepco P/N 104-0385, required for installation Four (4) required to install protective cover, Kepco P/N 137-0145. Standoff (Protective cover) 104-0385 Male/female, 8-32 x 1.5 in. long Setback Ear Brackets, 19 inch Rack Used to mount rack adapter in 19-inch rack using “set back”...
  • Page 15: Ra 19-4C Schematic Diagram

    AL COM3 JP28 AL COM4 SENSE CONNECTIONS DO NOT APPLY TO HSF 1200W AND 1500W JP18 JP27 AL COM2 AL COM3 AL COM4 UNITS. -COM1 -COM2 -COM2 -COM3 -COM3 -COM4 3020736 FIGURE 1-5. RA 19-4C SCHEMATIC DIAGRAM 6-6/6-7 1-7/1-8 (Blank) 120318...
  • Page 17: Ra 19-4C Mechanical Outline Dimensions

    B) BACK COVER ALUMINUM #14 GA. 2. FINISH: A) CHASSIS & COVER: CLEAR ZINC PLATED B) FRONT PANEL & ANGLE BKT: KEPCO GRAY, C) BACK COVER: CLEAR IRIDITE 3. RACK OR CABINET MOUNTING: REMOVE (4) PLASTIC FEET 4. DIMENSIONS IN PARENTHESES ARE IN MILLIMETERS.
  • Page 19: Section 2 - Installation

    2.4). RACK ADAPTER KEYING INSTRUCTIONS RA 19-4C rack adapters incorporate a keying mechanism to prevent accidental insertion of the incorrect model HSF power supply into any position. The HSF power supplies are keyed by volt- age at the factory. The keying mechanism will prevent engagement of any of the HSF power supply's connectors with those on the rack adapter's back plate unless the key and keyway align.
  • Page 20: Establishing Key Positions

    To establish the keying of any position, simply install the 4-40 x 0.75 in. thread-forming screws (Kepco P/N 101-0480) into the corresponding holes as indicated in Figure 2-1. DO NOT OVER- TIGHTEN these screws (max torque 5 in.-lbs. (0.6 N x m). DO NOT ALTER THE KEYING AT THE POWER SUPPLY.
  • Page 21: Independent Operation

    I/O mating connector as shown in Figure 2-2. Using external wiring at the I/O mat- ing connector allows configuration of non-adjacent slots. Use shielded wire for connections to RV pins. HSF 300W and 600W modules MUST have sense connections configured to work properly (see PAR. 2.4.1.2 RA 19-4C 120318...
  • Page 22: Sense Connections For Independent Operation (Hsf 300W And 600W Modules Only)

    (see Figure 2-3). Sensing for each slot can be configured independently: • Local sensing using internal DIP switches • Local sensing using external jumpers connected to the I/O mating connector or the DC OUTPUT terminal block. • Remote sensing RA 19-4C 120318...
  • Page 23: 2.4.1.2.1 Independent Operation - Local Sensing Using Internal Dip Switches

    OFF (open). Position 5 (current share) must be set to OFF and positions 6, 7, and 8 (alarms) can be configured per PAR. 2.5. FIGURE 2-3. INDEPENDENT OPERATION, LOCAL SENSING FOR PS1 AND PS2 USING INTERNAL DIP SWITCHES, SIMPLIFIED DIAGRAM RA 19-4C 120318...
  • Page 24: 2.4.1.2.2 Independent Operation - Local Sensing Using External Wiring

    Positions 3 and 4 (connecting sense lines in parallel) and Position 5 (current share) must be set to OFF. Configure Positions 6, 7, and 8 (alarms) per PAR. 2.5. FIGURE 2-4. INDEPENDENT OPERATION, LOCAL SENSING FOR PS1 AND PS2 USING EXTERNAL WIRING, SIMPLIFIED DIAGRAM RA 19-4C 120318...
  • Page 25: 2.4.1.2.3 Independent Operation - Remote Sensing

    Positions 3 and 4 (connecting sense lines in parallel) and Position 5 (current share) must be set to OFF. Configure Positions 6, 7, and 8 (alarms) per PAR. 2.5. FIGURE 2-5. INDEPENDENT OPERATION, REMOTE SENSING FOR PS1 AND PS2 USING EXTERNAL WIRING AT I/O MATING CONNECTOR OR EUROBLOCK, SIMPLIFIED DIAGRAM RA 19-4C 120318...
  • Page 26: Parallel Operation

    The impedance of the load wires between each power supply and load should be the same. In addition, multiple RA 19-4C rack adapters that are fully populated with identical HSF power supplies may be paralleled using external wiring at the I/O connectors.
  • Page 27 NOTE: When connections are made at the I/O mating connector, use shielded wire for con- nections to RV pins. Match impedance of load wires between each power supply and load by using the same wire lengths and wire sizes. RA 19-4C 120318...
  • Page 28: Single Load, Master Determined By Highest Output Voltage

    FIGURE 2-6. PARALLEL CONNECTION, INDIVIDUAL CONTROL, MASTER-SLAVE, SINGLE LOAD, MASTER DETERMINED BY HIGHEST OUTPUT VOLTAGE 2-10 RA 19-4C 120318...
  • Page 29: Parallel, Master Selected By User, Supplying Balanced Current To Asingle Load

    For group control requiring a redundant system Kepco recommends configuring all parallel con- nected units as slaves (see Table 2-3) controlled by a remote voltage. To eliminate a single point failure possibility the remote voltage should have a backup and be connected in parallel to more than one I/O connector.
  • Page 30: Voltage Control, Rv, Com And Cb Lines Paralleled By Rack Adapter Dip Switches

    FIGURE 2-7. PARALLEL, MASTER-SLAVE, SINGLE LOAD, HSF DIP SWITCHES DEFINE MASTER AND VOLTAGE CONTROL, RV, COM AND CB LINES PARALLELED BY RACK ADAPTER DIP SWITCHES 2-12 RA 19-4C 120318...
  • Page 31: Control, Rv, Com And Cb Lines Paralleled By External Wiring At I/O Connector

    FIGURE 2-8. MASTER-SLAVE, SINGLE LOAD, HSF DIP SWITCHES DEFINE MASTER AND VOLTAGE CONTROL, RV, COM AND CB LINES PARALLELED BY EXTERNAL WIRING AT I/O CONNECTOR 2-13 RA 19-4C 120318...
  • Page 32: Current Balancing

    For remote sensing (at the load) connect the sense lines in parallel using either the DIP switches or external jumpers to connect the sense lines in parallel, then connect one +S and one –S from the I/O connector to the load using external wires. 2-14 RA 19-4C 120318...
  • Page 33: Parallel Configuration Using Dip Switches To Connect Sense Lines In Parallel

    6. For local sensing connect wire between one I/O mating connector pin 11 (S–) or Euro Mating plug (S–) and corresponding power supply (–) output terminal or bus bar. For remote sensing connect wire between one I/O mating connector pin 11 (S–) or Euro Mating plug (S–) and corresponding load (–) terminal. 2-15 RA 19-4C 120318...
  • Page 34: Sensing And Dip Switches To Parallel Sense Wires (Hsf 300W And 600W Only)

    FIGURE 2-9. TYPICAL PARALLEL CONNECTIONS USING EXTERNAL WIRES FOR LOCAL/REMOTE SENSING AND DIP SWITCHES TO PARALLEL SENSE WIRES (HSF 300W AND 600W ONLY) 2-16 RA 19-4C 120318...
  • Page 35: Parallel Configurations Using External Wires To Connect Sense Lines In Parallel (Hsf 300W And 600W Only)

    8. For local sensing connect wire between one I/O mating connector pin 11 (S–) or Euro Mating plug (S–) and corresponding power supply (–) output terminal or bus bar. For remote sensing connect wire between one I/O mating connector pin 11 (S–) or Euro Mating plug (S–) and corresponding load (–) terminal. 2-17 RA 19-4C 120318...
  • Page 36: Sensing And I/O Mating Connector Jumpers To Parallel Sense Wires (Hsf 300W And 600W Only)

    FIGURE 2-10. TYPICAL PARALLEL CONNECTIONS USING EXTERNAL WIRES FOR LOCAL/REMOTE SENSING AND I/O MATING CONNECTOR JUMPERS TO PARALLEL SENSE WIRES (HSF 300W AND 600W ONLY) 2-18 RA 19-4C 120318...
  • Page 37: Series Connection

    2.4.3 SERIES CONNECTION HSF power supplies may be connected in series to obtain higher output voltages. The RA 19-4C rack adapter is designed to safely handle a maximum output voltage of 500 Volts; contact Kepco Applications Engineering for additional information. The power supply with the lowest rated value of maximum current establishes the maximum load current allowed.
  • Page 38: Series Connection

    FIGURE 2-11. SERIES CONNECTION 2-20 RA 19-4C 120318...
  • Page 39: Alarm Configurations

    (COM) for use as an alarm at the users discretion. The N.C. line opens upon failure, the N.O. line closes upon failure. The RA 19-4C is configured at the factory for independent operation of these lines. It is possible to configure these alarm lines to allow multi- ple power supplies to provide a failure indication using the N.O.
  • Page 40: With Output From I/O Mating Connector, Simplified Diagram

    FIGURE 2-12. TYPICAL CLOSE ON FAILURE ALARM CONFIGURATION USING REAR PANEL DIP SWITCHES WITH OUTPUT FROM I/O MATING CONNECTOR, SIMPLIFIED DIAGRAM 2-22 RA 19-4C 120318...
  • Page 41: Switches, With Output From Alarm I/O Terminal Blocks, Simplified Diagram

    FIGURE 2-13. TYPICAL CLOSE ON FAILURE ALARM CONFIGURATION USING REAR PANEL DIP SWITCHES, WITH OUTPUT FROM ALARM I/O TERMINAL BLOCKS, SIMPLIFIED DIAGRAM 2-23 RA 19-4C 120318...
  • Page 42: Close On Failure Using External Wiring At I/O Mating Connector

    N.O. and COM lines. Figure 2-14 is a simplified diagram illustrating a close on failure alarm configuration for four power supplies using external wiring at the I/O mat- ing connector. FIGURE 2-14. CLOSE ON FAILURE ALARM CONFIGURATION USING EXTERNAL WIRING AT I/O MATING CONNECTOR, SIMPLIFIED DIAGRAM 2-24 RA 19-4C 120318...
  • Page 43: Close On Failure Using External Wiring At Alarm I/O Terminal Block

    To configure multiple power supplies so that a failure of any supply produces a failure indication, it is necessary to connect the N.C. line with the COM line of the next power supply, so the alarm line is connected in series. 2-25 RA 19-4C 120318...
  • Page 44: Open On Failure Using Rear Panel Dip Switches

    DIP 3, and DIP 4 to ON (closed). The failure indication (open circuit) will be present across N.C.4 and COM 1. FIGURE 2-16. TYPICAL OPEN ON FAILURE ALARM CONFIGURATION USING REAR PANEL DIP SWITCHES WITH OUTPUT FROM I/O MATING CONNECTOR, SIMPLIFIED DIAGRAM 2-26 RA 19-4C 120318...
  • Page 45: With Output From Alarm I/O Terminal Blocks, Simplified Diagram

    FIGURE 2-17. TYPICAL OPEN ON FAILURE ALARM CONFIGURATION USING REAR PANEL DIP SWITCHES WITH OUTPUT FROM ALARM I/O TERMINAL BLOCKS, SIMPLIFIED DIAGRAM 2-27 RA 19-4C 120318...
  • Page 46: Open On Failure Using External Wiring Of I/O Mating Connector

    It is necessary to set DIP switch position 8 to OFF (open) for each slot included in the open on failure alarm circuit. FIGURE 2-18. OPEN ON FAILURE ALARM CONFIGURATION USING EXTERNAL WIRING AT I/O MATING CONNECTOR, SIMPLIFIED DIAGRAM 2-28 RA 19-4C 120318...
  • Page 47: Open On Failure Using External Wiring Of I/O Alarm Terminal Blocks

    HSF power supplies. Kepco recom- mends providing additional space above and below the rack adapter where possible when the rack adapter is fully populated.
  • Page 48: Installation

    2.8.1 INSTALLING OPTIONAL PROTECTIVE COVER (Refer to Figure 2-20.) A clear plastic cover (Kepco P/N 137-0145) is available as an accessory to protect the rear ter- minals against accidental contact. Four standoffs (minimum) (Kepco P/N 104-0385) are required for installation.
  • Page 49: Optional Protective Cover Or Parallel Bus Bar Installation

    (0.875 IN. DIA. HOLE). C - CUTOUT FOR I/O CONNECTOR CABLE. D - CUTOUT FOR CABLE EXIT. E - LOCKING TAB. 3043095 FIGURE 2-20. OPTIONAL PROTECTIVE COVER OR PARALLEL BUS BAR INSTALLATION FIGURE 2-21. SERIES BUS BAR INSTALLATION 2-31 RA 19-4C 120318...
  • Page 50: Installing Optional Locking Bracket

    Use of this bracket will increase the time required to remove and replace a module, and there is a possibility the rack adapter may be scratched during the process; contact Kepco applications engineering to be sure this bracket is the right solution.
  • Page 51: Installing Hsf Power Supplies

    NOTE: If optional locking bracket is in use, refer to PAR. 2.8.3 for power supply installation. Refer to Figure 1-1, for proper slot positions applicable to the RA 19-4C Rack Adapter. With the retaining latches disengaged (at the top of the slot) as described above, insert HSF power sup- ply in selected slot until power supply front panel is flush with rack adapter chassis, then secure the retaining latches as described above.
  • Page 52: Safety Grounding

    2.11.2 SOURCE POWER CONNECTIONS The RA 19-4C rack adapter is designed to be used in conjunction with Kepco HSF series power supplies. Source power requirements are determined by the HSF power supply (see HSF power supply Instruction Manual); no adjustment or modification of the rack adapter is required.
  • Page 53: Emi Compliance

    FCC Class B. It may be necessary to add external source power filtering, such as installing snap-on ferrite beads on the line cord wires of the RA 19-4C as close to the input a-c terminal block as possible. Another option is to add an in-line cabinet-mounted EMI filter (available from a number of manufacturers) between the source power and the RA 19-4C line cord.
  • Page 54: Parallel/Redundant Operation

    2.11.4.4 MIXED OPERATION The design of the RA 19-4C rack adapters permits the user to configure HSF power supplies for almost any combination of independent, series and parallel operation, both within a single rack adapter and between different RA 19-4C rack adapters, within the limits of the HSF operation envelope and the current and voltage ratings specified in PAR.s 2.11.4.2 and 2.11.4.3.
  • Page 55: Ripple And Noise Measurement Setup Diagram

    (see NOTE to PAR. 2.9). Contact Kepco Applications Engineering if further assistance is required. Without power supplies the rack adapter weighs 16 lbs. (7.3Kg). FIGURE 2-23. RIPPLE AND NOISE MEASUREMENT SETUP DIAGRAM 2-37/(2-38 Blank) RA 19-4C 120318...