Panasonic UF-585 Service Manual page 144

Panasonic uf-585; uf-595 facsimile
Hide thumbs Also See for UF-585:
Table of Contents

Advertisement

No.
Parameter (see Note 3)
000
MON/TEL DIAL
001
ALARM STATUS
002
STOP COMM. JRNL
003
CONTINUOUS POLL
004
NUMERIC ID SET
005
Not Used
006
ID DISPLAY
007
JNL COLUMN
008
MONITOR
009
DC LOOP
010
TX LEVEL
011
RX LEVEL
012
DTMF LEVEL
013
G3 RX EQL
014
G3 TX EQL
015
Not Used
~
016
Function Parameter Table
Selections
1 = Monitor
2 = TEL/DIAL
1 = Off
2 = Timer (6 sec.)
3 = Constant
1 = Off
2 = On
1 = Off
2 = Stn (Tx only)
1 = Off (will not accept)
2 = On (accepts)
1 = Number (Numeric ID)
2 = Chara (Character ID)
1 = Preset station name
2 = Received ID
1 = Off
2 = On
1 = Off (Normal)
2 = On (Off Hook)
00 = 0 dBm
~
15 = -15 dBm
1 = -43 dBm
2 = -38 dBm
3 = -33 dBm
4 = -48 dBm
00 = 0 dBm
~
15 = -15 dBm
[UF-595]
1 = 0dB
2 = 4dB
3 = 8dB
4 = 12dB
[UF-585]
1 = Off
2 = On
[UF-595]
1 = 0dB
2 = 4dB
3 = 8dB
4 = 12dB
[UF-585]
1 = Off
2 = On
144
Function
Selects whether the machine starts to TX
automatically during On-Hook dialing.
(Monitor: Start to TX after pressing START)
(TEL/DIAL: Start to TX automatically)
Selects the operation of the alarm status.
OFF : Alarm is disabled.
Timer : Alarm will shut off after 6 seconds.
Constant : Alarm will not stop until "STOP" is
pressed or the error is cleared/corrected.
Selects whether the machine prompts to print the
COMM. Journal when the printout condition is set
to INC and STOP is pressed during
communication.
Selects whether the Continuous Polling feature is
enabled.
Stn:
Place the document(s) on the ADF then press the
Program Key [P4] to store or add the document(s)
into a polled file. (See Note 4)
Selects whether the machine accepts and allows to
set or change the Numeric ID.
Selects the priority of displaying the ID.
Selects the contents of the ID to display on the
Journal.
Selects whether the Monitor is ON/OFF for monitor-
ing fax signals.
(FOR SERVICE USE ONLY)
Selects a false Off Hook state for back to back
communication test.
Selects the TX signal output level, 0 to -15 dBm in 1
dBm steps. (Refer to Chapter 4.3)
Selects the receiving sensitivity of -33/-38/-43/-48
dBm.
(Refer to Chapter 4.3)
Selects the DTMF output level, 0 to -15 dBm in 1
dBm steps.
Selects the cable equalizer for G3 reception mode.
UF-595: 1:0dB
2:4dB
3:8dB
4:12dB
UF-585: 1:Off
2:On (7.2 Km)
Selects the cable equalizer for G3 transmission
mode.
UF-595 : 1:0dB
2:4dB
3:8dB
4:12dB
UF-585 : 1:Off
2:On (7.2 Km)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Uf-595

Table of Contents