Optocore DD2FR-FX Operating Manual

Dual madi / sane / video / data module with ethernet

Advertisement

Quick Links

Operating Manual for OPTOCORE DD2FR-FX
DUAL MADI / SANE / VIDEO / DATA MODULE WITH ETHERNET
Optical Digital Network Device
© Copyright 2015 All rights reserved
OPTOCORE GmbH
Lohenstr. 8
82166 Munich-Gräfelfing
Germany
DD2FR-FX
Operating Manual
Rev. 2.1

Advertisement

Table of Contents
loading

Summary of Contents for Optocore DD2FR-FX

  • Page 1 Operating Manual for OPTOCORE DD2FR-FX DUAL MADI / SANE / VIDEO / DATA MODULE WITH ETHERNET Optical Digital Network Device © Copyright 2015 All rights reserved OPTOCORE GmbH Lohenstr. 8 82166 Munich-Gräfelfing Germany DD2FR-FX Operating Manual Rev. 2.1...
  • Page 2 Page intentionally left blank.
  • Page 3: Important Safety Instructions

    • Never switch on power amplifiers before the complete system is stable and the level meters of the OPTOCORE CONTROL software indicate a normal level. • Do not place this device on an unstable table, tripod, cart, etc. The device may fall, causing serious damage to the device.
  • Page 4: Purchaser Information

    Leave sufficient space (minimum ½ RU) between the device and any heat emitting devices housed in the same rack. A DD2FR-FX may be placed on top or beneath other Optocore products,. except a DD32E, without additional space for up to 4 adjacent rack spaces.
  • Page 5 Never push objects of any kind into the device through openings in the casing. They may come into contact with dangerous voltage points or short out parts that could result in fire or electric shock. Never spill liquid of any kind on the device. DD2FR-FX 5 / 25 rev. 2.1...
  • Page 6 Such operation can lead to damage of the device’s components due to lack of air-flow through the device. The device may not be serviced, altered or modified without authorization from Optocore or an Optocore authorized distributor / dealer. Only qualified service personnel may carry out repair and maintenance work on the device.
  • Page 7: Ce/Fcc-Conformity

    Operation of this equipment in a residential area is likely to cause harmful interference, in which case you will be required to correct the interference at his own expense. Changes or modifications not expressly approved by Optocore GmbH could void the user’s authority to operate this equipment.
  • Page 8 Page intentionally left blank.
  • Page 9: Table Of Contents

    DD2FR-FX – Dual Fiber MADI device for Optocore and SANE Table of Contents Important Safety Instructions ........................... 3 Purchaser Information.............................. 4 CE/FCC-Conformity ..............................7 Device Description ..............................10 Front Panel ................................12 Rear Panel................................13 Device Details ................................ 14 Optocore Fibre Optic Connection ....................... 14 MADI Ports ..............................
  • Page 10: Device Description

    The DD2FR-FX enables connectivity to the SANE network via RJ45 ports. It is possible to use SANE as a Cat5 based cost-efficient extension to the optical core system. SANE ports may be used as point-to-point MADI over Cat5 or as a bridge interface between SANE and OPTOCORE, providing in total up to 128 input and 128 output additional channels.
  • Page 11 This allows the devices internal logic to be updated, in the field, ensuring a continual state-of-the-art device. Optocore devices, and complete networks, are configured and operated using the OPTOCORE CONTROL software. The software provides access to all configuration parameters and controls needed to operate the system, including: naming channels, setting gains and phantom power, routing as well as recall and capture of partial or full system configurations.
  • Page 12: Front Panel

    Communication is established via SANE 1 (rear panel) SL2: Communication is established via SANE 2 (rear panel) OL1: Communication is established via Optocore LINK 1 (rear panel) OL2: Communication is established via Optocore LINK 2 (rear panel) System status Master LED:...
  • Page 13: Rear Panel

    RS485: 4 x RS485/RS422 (D-Sub-9) auxiliary port for data transmission Word Clock IN: BNC Word clock input allowing synchronization of Optocore devices/network from an external word clock source Word Clock OUT: BNC Word clock output for synchronization of external devices...
  • Page 14: Device Details

    MADI in groups of eight. LEDs on the front panel of the DD2FR-FX indicate the number of channels received at the MADI input ports. The MADI output ports always transmit the complete frame with 56 or 64 audio channels according to the standard.
  • Page 15: Power Supply

    Transmission Delay The Optocore system delay including the matrix is fixed to 41,6 µs @ 48 kHz for all channels. The additional transport delay per Optocore unit (<200 ns) in the network is insignificant in comparison. Overall system delay is dependent on the converters used and the length of network cables in the system.
  • Page 16: Sane Bandwidth Allocation

    SANE bandwidth allocation The standard bandwidth allocation of a SANE link is as follows: Audio 64 Channels @ 48 KHz Ethernet 100 MBit Fast Ethernet DD2FR-FX 16 / 25 rev. 2.1...
  • Page 17: Connectors And Cables

    The MADI-interfaces are equipped with SC multimode optical connectors. Standard SC cables are perfectly suitable for interconnection of devices. It is recommended to use multimode cable for MADI connectivity. The MADI transceiver provided by Optocore supports both multi-mode and single-mode connectivity as long as the multimode cable is used.
  • Page 18: Hardware Connection

    If the DD2FR-FXs and other Optocore devices are pre-configured, the network is ready to work. With a PC connected to any unit in the loop and by running the OPTOCORE CONTROL software, the network may be analyzed, supervised, parameters may be changed and the matrix can be accessed for signal-routing.
  • Page 19: Network Examples

    Studer signals can be transported similar to the examples below. Connecting AVID console with its stagerack requires a special firmware version, which supports AVID’s Snake protocol. Fig. 3: Redundant network with two DD2FR-FX in a 64 send / 64 return configuration with Lawo and Soundcraft...
  • Page 20 Connection between console’s Local rack and OPTOCORE NETWORK is made using MADI digital signal. Fig. 4: Redundant network with one DD2FR-FX and four X6R-FXs. 48 analog inputs and 16 analog outputs are available at the X6R-FXs For more details regarding the connecting of 3...
  • Page 21 Power Internally Channel Bridged Use 1-modem cable, male – female, to +5VS connect to PC 1, 4, 6 7, 8 D-Sub-9- female Locking system acc. to 4-40 UNC Pin-out USB-Port Channel USB device-connector VBUS DD2FR-FX 21 / 25 rev. 2.1...
  • Page 22 BI-C Cable The D-Sub-9 BI-C enables the bi-directional transmission of control data between DD2FR-FX and Yamaha HA Remote port. The RS485 Ports 3 and 4 of the DD2FR-FX are used. DD2FR-FX Auxiliary Port 4 x RS485 COM RS422 X3...X4: I/Os...
  • Page 23: Technical Specifications

    USB 2.0 - Device 12 Mbit/s TIA-568A/B, IEEE - 802.3 10/100 Mbit/s SANE, LAN Convention Audio TIA - 568A/B, Optocore 200 Mbit/s TIA - 568A/B, IEEE - 802.3 10/100 Mbit/s Optical Connection Complies with 21 CFR 1040.10 and 1040.11 Power supply...
  • Page 24: Warranty And Liability

    The warranty will be void if you tamper with internal components. Please address any questions or inquiries to OPTOCORE or your distributor/dealer. For a full warranty conditions refer to the Warranty Card attached to every Optocore device with a first shipment. How to Obtain Warranty Service When discovering a problem with an OPTOCORE device, you should contact either Optocore directly or a dealer/distributor to determine and confirm a hardware fault.
  • Page 25: Shipping Contents

    Shipping Contents The standard shipment of a DD2FR-FX unit contains the following: • 1 DD2FR-FX unit • 1 operators manual • 1 fibre patch cable LC-LC • 2 power cables (according to number of PSU units installed) Any additionally purchased equipment such as optical wave-guide cables in required lengths, D-Sub cables and adapters, RS232 cables, and international electric cables which have been supplied on your request and your purchase order, cannot be listed above.

Table of Contents