How To Use "Push-In" Connectors; How To Use "Inlet/Outlet" Fitting/Retention Clip; Equipment Installation - 3M Triple Manifold Water Filtration Systems Instruction Manual

High flow series water filtration systems
Table of Contents

Advertisement

How to Use "Push-in" Connectors

This product is outfitted with a user friendly 'Push In' connector at the vent valve. Proper use of the connectors is
shown in the figure below. It is most important that the tubing selected for use with these connectors be of high
quality, exact size and roundness, and with no surface nicks or scratches. If it is necessary to cut the tubing, use a
plastic tubing cutter or sharp razor knife. Make a clean square cut. Should a leak occur at a "Push-In" connec-
tor, the cause is usually a problem with tubing.
To Fix:
1. Relieve pressure
4. Reattach tubing
To Attach Tubing
1
Push tubing straight in as far
as it will go.
How to Use the Inlet/Outlet Fitting and Retention Clips
This product is outfitted with inlet/outlet fittings. The fittings can be attached or removed from the system with-
out tools. Retention clips are semi-circular in shape with three internal tabs, bottom, center and top. Tab interfaces
with windows in the manifold head near each connection port clip is flexible and easily assembled following these
instruction and illustrations.
1. Insert fitting into manifold.
2. With fitting inserted into manifold port, snap clip into place beginning at the bottom window
3. Push center tab into center window.
4. Finally push top tab into top window.
Step 1

Equipment Installation

o reduce the risk associated with property damage due to water leakage:
T
Do not use a torch or other high temperature sources near filter system, cartridges, plastic fittings or plastic
plumbing.
deteriorate plastic.
Take care when using pliers or pipe wrenches to tighten plastic fittings, as damage may occur if overtight-
ening occurs..
install near water pipes which will be in path of a drilling tool when selecting the position to mount the system
Mount filter in such a position as to prevent it from being struck by other items used in the area of installation.
Ensure that the location and fasteners will support the weight of the system when installed.
Ensure all tubing and fittings are secure and free of leaks.
2. Release tubing
5. Confirm connection is leak free
To Release Tubing
2
Push in collt to release tubing.
Tubing is secured in.
Step 2
CAUTION
3. Cut off at least 1/4" from end
1
2
Pull tubing straight out.
Step 3
only, pipe dope properties may
5
Step 4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dual manifold water filtration systems

Table of Contents