nubeca BA2115 Instruction Manual

Fully automatic upper arm style

Advertisement

Quick Links

Model No.:BA2115
A01

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BA2115 and is the answer not in the manual?

Questions and answers

Summary of Contents for nubeca BA2115

  • Page 1 Model No.:BA2115...
  • Page 2: Table Of Contents

    Before Using the Monitor Introduction ....................1 Thank you for purchasing Fully Automatic Upper Arm Style Digital Symbols Use .....................2 Blood Pressure Monitor. Important Safety Notes ................3 K now Your Unit ..................4-5 The unit uses the oscillometric method of blood pressure IHB Introduction ..................6 measurement.
  • Page 3: Symbols Use

    Symbols Use SYMBOLS USED IN THIS INSTRUCTION MANUAL To assure the correct use of the product basic safety measures Indicates a potentially hazardous situation which, if not should always be followed including the precautions listed below: WARNING avoided, could result in death or serious injury. Indicates a potentially hazardous situation which, if not Read all information in the instruction manual and any other avoided, may result in minor or moderate injury to the user or...
  • Page 4: Know Your Unit

    Know Your Unit Know Your Unit Body Arm Cuff Air Plug Display (Insert to Air Socket) Fit for 22cm~32cm range of upper arm perimeter Air Socket START/STOP Button Hose Setting Button Memory Button Metal If your arm cuff is broken or not functional, please use a new cuff. A new arm cuff does not include an air plug.
  • Page 5: Ihb Introduction

    IHB Introduction Before Taking A Measurement 1.Avoid eating,drinking alcohol, smoking, exercising and bathing for Irregular Heartbeat Symbol( 30 minutes before taking a measurement. 2.Stress raises blood pressure. Avoid taking measurements during When the unit detects an irregular rhythm two or more times during stressful times.
  • Page 6 Install 4 “AA” size batteries so the + (positive) and - (negative) polarities match the polarities of the battery compartment as indicated. Replace the battery cover. Press the “START/STOP” button. All symbols appear,then the cuff starts to inflate automatically. BA2115...
  • Page 7: Adjusting Settings

    1.1 All information will appear when the batteries are installed at the first time.After 2 seconds the year flashes. BA2115 Finally, press the “SET” button and continue with step 2. BA2115 1.2 The mark of year appears and flashes after press the “SET”...
  • Page 8: To Set Unit

    BA2115 4. To set unit Then press the “MEM” button to change the current unit. (kPa You can stop the setting anytime when you press the “START/STOP” or mmHg) button to save the current setting and turn off.
  • Page 9: Proper Use Of The Arm Cuff

    Proper Use of the Arm Cuff Proper Use of the Arm Cuff Put your arm through the loop, then pull it up to the Make sure the air plug is position of your upper arm. inserted properly in the main unit. The hose runs down the Remove all clothes from inside of your arm.
  • Page 10: Take A Measurement

    Press the “START/STOP” button to turn off the unit. All display symbols appear. The cuff starts to inflate automatically. The unit will automatically turn off after 2 minutes if you have forgotten to turn it off. BA2115 BA2115 NOTE: Inflation stop automatically and the measurement is To stop the inflation or measurement, press the “START/STOP”...
  • Page 11: Use The Memory Function

    To read the average value Press the “MEM” button. The average value symbol will display. Turn to next BA2115 BA2115 the average value of the latest Note: if you have set “ ”, but do not press a button for 2 minutes, 3 times measurement taken the product will shut off automatically, but the corresponding user’s...
  • Page 12: About Blood Pressure

    About Blood Pressure About Blood Pressure Classification of Blood Pressure Blood Circulation After each measurement is completed, the LCD display will show your The blood circulation is responsible for supplying the body with oxygen. position automatically on the six segments of the bar indicator which Blood pressure is the pressure exerted on the arteries.
  • Page 13: Care And Maintenance

    Exceptional Situations Care and Maintenance Care Error Indicators Keep the unit in the storage case The following symbol will appear on the display when measuring abnormally. when not in use. Clean the unit with a soft dry cloth. Symbol Cause Correction Do not use any abrasive or volatile cleaners.
  • Page 14: Statement

    Statement BA2115 The unit is intended to be used to measure blood pressure (systolic and diastolic) and heart rate from the upper arm by using the oscillometric method. The unit is intended for usingin only adult population,not applied to the other populations such as neonatal baby.
  • Page 15: Emc Table

    EMC Table EMC Table Guidance and manufacture’s declaration IEC 60601 test Compliance Guidance and manufacture’s declaration – electromagnetic emission Immunity test Electromagnetic environment - guidance level level The Digital Blood Pressure Monitor is intended for use in the electromagnetic environment Portable and mobile RF communications specified below.
  • Page 16: Warranty Information

    EMC Table Warranty Information Recommended separation distances between The unit, excluding the unit cuff, is guaranteed to be free of defects in portable and mobile RF communications equipment and the Digital Blood Pressure Monitor. workmanship and materials for a period of two years from the date Pressure Monitor is intended for use in an electromagnetic environment in which radiated listed on the purchase record, when used in accordance with the RF disturbances are controlled.

Table of Contents