Control Valve Instructions; To Set Time Of Day; To Set Time Of Regeneration And Days Between Regeneration - Diamond H2O DCF6-100-100 Installation, Operation And Maintenance Manual

Activated carbon water filter system
Table of Contents

Advertisement

5. CONTROL VALVE INSTRUCTIONS

5.2.

TO SET TIME OF DAY

In the event of a prolonged power outage, time of day flashes,
indicating that it needs to be reset. All other information will
be stored in memory no matter how long the power outage.
Please complete the steps as shown to the right. To access
this mode, press "SET."
1. Accessed by pressing SET for approximately 3 seconds.
2. Adjust hour with ▲ or ▼ buttons. With 60 Hz line
frequency detection on power-up, timekeeping is 12
hour with PM indicator. With 50 Hz line frequency
detection on power-up, timekeeping is 24 hour without
the PM indicator. Press SET to go to the next step.
3. Adjust minutes with ▲ or ▼ buttons.
4. Press SET to complete and return to normal operation.
5.2.

TO SET TIME OF REGENERATION AND DAYS BETWEEN REGENERATION

For initial set-up or to make adjustments, please complete the
steps as shown.
Access this mode by pressing the SET and ▲ buttons for
approximately 3 seconds.
The number of days between regenerations may need to be
varied based on usage and water conditions. (This step will not
appear if the 7-day clock option is selected.)
1. Accessed by pressing the SET and ▲ buttons
simultaneously for about 3 seconds.
2. Set Regeneration Time Hour. Set the time for
regeneration to start. Press the SET button to go to the
next step.
3. Set Regeneration Time Minutes. Press the SET button to
go to the next step.
4. Set number of Days between regeneration cycles.
5. Press SET to complete and return to normal operation.
N1022 Quality Drive
Diamond H2O
/
PO Box 170
Ph: (920) 757-5440 / (866) 757-9287 / Fax: (920) 757-5819
/
Greenville, WI 54942
Page 6

Advertisement

Table of Contents
loading

Table of Contents