4. Remove the 4 screws holding magnetron.
5. Remove 2 screws holding thermal cutout.
6. Remove the air guide from magnetron and install it on the new
magnetron.
NOTE
To prevent microwave leakage, tighten mounting screws properly making sure there is no gap between
the waveguide and the magnetron.
When connecting 2 filament lead wires to the
magnetron terminals, be sure to connect the lead
wires in the correct position. The lead wire with
blue connector should be connected to "FA
terminal" and white one should be connected to "F
terminal". (See Figure)
Created with novaPDF Printer (www.novaPDF.com). Please register to remove this message.