Advertisement

Operating and installation instructions
Rangehood
To prevent the risk of accidents or damage to the appliance, it is
essential to read these instructions before it is installed and used for
the first time.
en-AU, NZ
M.-Nr. 09 705 590

Advertisement

Table of Contents
loading

Summary of Contents for Miele DA 396-6

  • Page 1 Operating and installation instructions Rangehood To prevent the risk of accidents or damage to the appliance, it is essential to read these instructions before it is installed and used for the first time. en-AU, NZ M.-Nr. 09 705 590...
  • Page 2: Table Of Contents

    Contents Warning and Safety instructions................3 Caring for the environment................. 12 Description of the functions................13 Guide to the appliance..................14 Operation......................16 Switching the fan on....................16 Selecting a power level..................16 Switching the fan off....................17 Switching the cooktop lighting on/off..............17 Safety switch-off....................
  • Page 3: Warning And Safety Instructions

     It must only be used to extract vapours and remove odours from cooking. Any other usage is at the owner's risk. Miele cannot be held liable for damage resulting from incorrect or improper use or operation.  This appliance is not intended for use by persons (including...
  • Page 4 Warning and Safety instructions Safety with children  Young children must not be allowed to use this appliance.  Older children may only use the appliance when its operation has been clearly explained to them and they are able to use it safely, recognising the dangers of misuse.
  • Page 5  Repairs and other work by unqualified persons could be dangerous. Installation, maintenance work and repairs to electrical appliances must only be carried out by a Miele approved service technician.  A damaged appliance can be dangerous. Check it for visible signs of damage.
  • Page 6 Miele replacement parts are used.  If the electrical connection cable is faulty, it must only be replaced by a Miele authorised service technician to protect the user from danger.  During installation, maintenance and repair work, the appliance must be disconnected from the mains electricity supply.
  • Page 7 Warning and Safety instructions Using at the same time as other heating appliances that depend on the air from the room  Warning - danger of toxic fumes Great care should be taken when using the rangehood at the same time and in the same room or area of the house as another heating appliance which depends on the air in the room.
  • Page 8 Warning and Safety instructions In order to ensure safe operation, and to prevent gases given off by the heating appliances from being drawn back into the room when the rangehood and the heater are in operation simultaneously, an underpressure in the room of 0.04 mbar (4 pa) is the maximum permissible.
  • Page 9 Warning and Safety instructions Correct use  Never use an open flame beneath the rangehood. To avoid the danger of fire, do not flambé or grill over an open flame. When switched on, the rangehood could draw flames into the filter. Fat deposits could ignite, presenting a fire hazard.
  • Page 10 Warning and Safety instructions  Do not use the rangehood without the filters in place. This way you will avoid the risk of grease and dirt getting into the appliance and hindering its smooth operation.  The filters should be regularly cleaned or changed as appropriate. Saturated filters are a fire hazard.
  • Page 11 The steam could reach electrical components and cause a short circuit. Accessories  Use only genuine original Miele spare parts. If spare parts or accessories from other manufacturers are used, the warranty will be invalidated, and Miele cannot accept liability.
  • Page 12: Caring For The Environment

    Caring for the environment Disposal of the packing Disposing of your old material appliance The transport and protective packing Electrical and electronic appliances has been selected from materials which often contain materials which, if are environmentally friendly for handled or disposed of incorrectly, disposal, and can normally be recycled.
  • Page 13: Description Of The Functions

    Miele external motor located in a suitable position outside the room in which the rangehood is installed. The...
  • Page 14: Guide To The Appliance

    Guide to the appliance...
  • Page 15 Guide to the appliance a Telescopic extension piece b Tower c Canopy d Oven controls e Grease filters f Recirculation grilles (only for recirculation mode) g Cooktop lighting h NoSmell active charcoal filter (special accessory for recirculation mode) i On/Off touch control for the fan j Touch controls to select the fan power setting k On/Off touch control for the cooktop lighting...
  • Page 16: Operation

    Operation Switching the fan on Automatic switch-off of the Intensive setting  Press the On/Off touch control . You can set the Intensive setting so that The fan will switch on at setting 2. The it always only runs for 10 minutes ...
  • Page 17: Switching The Fan Off

    Operation Switching the fan off  Press the On/Off touch control  to switch the fan off. The  symbol will go out. Switching the cooktop lighting on/off The cooktop lighting can be switched on and off independently of the fan. ...
  • Page 18: Cleaning And Care

     To help prevent re-soiling, a  Switch the rangehood off before any proprietary conditioning agent for cleaning or maintenance work is stainless steel (Original Miele Care carried out product for stainless steel) can also  All external surfaces and controls can be used.
  • Page 19: Grease Filters

    Cleaning and care Controls Grease filters The re-usable metal grease filters in the Do not leave soiling on the controls appliance remove solid particles for any length of time. (grease, dust, etc.) from the kitchen Otherwise they may suffer vapours, preventing soiling of the discolouration or damage.
  • Page 20 Cleaning and care Cleaning the grease filters by hand After cleaning  Clean the filters with a soft nylon  After cleaning, leave the filters to dry brush in a mild solution of hot water on an absorbent surface before and a small amount of washing-up refitting them.
  • Page 21: Nosmell Active Charcoal Filter

    6 months. above the grease filters. Replacement charcoal filters can be Disposing of the charcoal filter obtained from Miele or via the internet  The used charcoal filter can be at www.miele-shop.com (depending on disposed of with the normal country).
  • Page 22: Changing A Halogen Lamp

    Cleaning and care Changing a halogen lamp  Remove the grease filters. The halogen lights become very hot during operation. It can cause burns even after being switched off for some time. Allow them to cool down for a few minutes before changing them.
  • Page 23: Installation

    Installation Before installation Dismantling Should the appliance ever need to be  Before installation, it is important dismantled, follow the installation to read the information given on the instructions in reverse order as following pages as well as the described on the installation sheet. A "Warning and Safety instructions"...
  • Page 24: Assembly Parts

    Installation Assembly parts...
  • Page 25 Installation a 3 protective sheets for use when fitting the tower. b 1 exhaust connection 8 screws, 5 x 60 mm and for exhaust ducting  150 mm. 8 plugs, 8 x 50 mm c 1 reducing collar for securing the wall bracket. for exhaust ducting ...
  • Page 26: Appliance Dimensions

    Installation Appliance dimensions The drawing is not to scale.
  • Page 27: Safety Distance (S)

    Installation a Extraction b Recirculation c Ventilation grille positioned at the top for recirculation de (only d is required for recirculation mode rangehoods): The shaded area represents the wall or ceiling area for the vent cut-out, for fitting the connection socket and on EXT models for feeding the connection cable through to the external motor.
  • Page 28: Installation Recommendations

    Installation Installation recommendations Drilling diagram for wall mounting – When deciding on the safety distance between the cooktop and  Please follow the directions given in rangehood, please note that a the installation instructions supplied distance of 650 mm above electric for drilling.
  • Page 29: Connection For Air Extraction

    Connection for air extraction A reduction in diameter will  Before installation, it is important compromise the extraction to read the information given on the performance of the rangehood. following pages as well as the "Appliance dimensions" and the – If flat ducting is being used, the "Warning and Safety instructions"...
  • Page 30: Condensate Trap

    Connection for air extraction  When ducting is horizontal it must be exhaust connection. laid to slope away at at least 1 cm The arrow on the housing indicates per metre. This is to ensure that the direction of airflow. condensate cannot drain back into The condensate trap will be integrated the rangehood.
  • Page 31 Connection for air extraction Recirculation mode The silencer needs to be positioned between the exhaust connection and the directional unit . Ensure there is adequate space in the tower for fitting Air extraction with external motor To minimise noise from the motor in the kitchen, the silencer should be positioned in front of the external motor ...
  • Page 32: Electrical Connection

    Electrical connection The rangehood must be connected to a suitably earthed socket (AC 230 V, 50 Hz). All electrical work should be undertaken by a suitably qualified and competent person in strict accordance with current national and local safety and building code regulations. Installation, repairs and other work by unqualified persons could be dangerous, for which the manufacturer...
  • Page 33: After Sales Service And Warranty

    After sales service and warranty In the event of a fault which you cannot remedy yourself, please contact Miele. The contact details for Miele are given at the back of these instructions. When contacting Miele, please quote the model and serial number of your appliance.
  • Page 34: Technical Data

    AC 230 V, 50 Hz Fuse rating 10 A Mains connection cable length 1.5 m Weight DA 396-6 21 kg DA 399-6 26 kg DA 399-6 EXT 24 kg Extraction power* according to EN 61591, extraction ducting  125/150 mm Setting 1 130/150 m³/h...
  • Page 36 DA 396-6 DA 399-6 DA 399-6 EXT  en-AU, NZ M.-Nr. 09 705 590 / 00...

This manual is also suitable for:

Da 399-6Da 399-6 ext

Table of Contents