SENKO SG-90 Instruction Manual

Solid fuel cookers
Hide thumbs Also See for SG-90:

Advertisement

Quick Links

Solid fuel
COOKERS
SG-75 and SG-90
SN-EN-04/14

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SG-90 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SENKO SG-90

  • Page 1 Solid fuel COOKERS SG-75 and SG-90 SN-EN-04/14...
  • Page 2 Dear client, thank you for choosing a SENKO cooker ! This product was designed and manufactured to its minutest details in order to fulfill your every need for functionality and safety. This Instruction manual will teach you to operate your cooker properly, so please read the manual carefully before using the cooker.
  • Page 3: Table Of Contents

    5.4. FIRING ................21 5.4.1. PROCEDURE .............21 5.4.2. OPTIMUM USE VALUES ................22 5.4.3. ADDING FUEL ..........23 5.4.4. FEEDING IN TRANSITION PERIOD ...................23 5.5. OVEN DOOR ..................24 5.6. FUEL BOX ..............25 5.7. HEIGHT ADJUSTMENT SENKO cookers SG-75 and SG-90 – Instruction manual...
  • Page 4 .................27 7.2. SPARE PARTS 8. MALFUNCTIONS / CAUSES / SOLUTIONS ........28 9. TECHNICAL SUPPORT ..............29 10. TECHNICAL DATA ................30 11. TERMS OF WARRANTY ..............31 WARRANTY ....................32 INSTALLATION REPORT .................33 CE MARKING ....................34 SENKO cookers SG-75 and SG-90 – Instruction manual...
  • Page 5: General

     E2190L SG-90 inox  E2190D SG-90 inox are models from the SENKO cookers palette which can accommodate your needs in the best possible way. Therefore, we ask you to CAREFULLY READ THESE INSTRUCTIONS, which will help you to achieve the best possible results already during the initial use.
  • Page 6 CF agent for removal of soot and grease from glass surfaces (24). figure 1 CAUTION! The cooker weighs between 130 and 200 kg. Extra caution is necessary when unloading, transferring, moving and installing the cooker in order to avoid physical injury. SENKO cookers SG-75 and SG-90 – Instruction manual...
  • Page 7: Fuel

     protective heat insulated gloves must also be used when opening and closing the oven and firebox door and removing the tray from the oven and ash box SENKO cookers SG-75 and SG-90 – Instruction manual...
  • Page 8: Chimney

    (backflow) because the counter pressure occurs here. Therefore, it is necessary to adhere to limitations listed in figure 2,  mechanical appliances for flue gases suction are not allowed. SENKO cookers SG-75 and SG-90 – Instruction manual...
  • Page 9: Chimney Function

    Apart from the pressure caused by the temperature difference between the flue gases and the outer chimney air, there is another type of pressure – wind dynamic pressure. SENKO cookers SG-75 and SG-90 – Instruction manual...
  • Page 10 (A). Contrary to that, underpressure can occur in lee rooms (C), adversely affecting functions of the chimney situated on the opposite side (D) from the wind direction. SENKO cookers SG-75 and SG-90 – Instruction manual...
  • Page 11: Insulation

    Manual). Special attention must be paid that there is enough air for combustion being supplied to the room cooker is installed in. SENKO cookers SG-75 and SG-90 – Instruction manual...
  • Page 12: Technical Features

    3. TECHNICAL FEATURES SG-75 and SG-90 SENKO cookers are intended for cooking, baking and household heating. They are equipped with an oven just like the traditional kitchen cooker. Cookers are suitable for installation between other kitchen appliances without heating risks.
  • Page 13 24. CF agent for removal of soot 15. Handle for grate moving Lower door and grease from glass 16. Movable grate Firebox door SENKO cookers SG-75 and SG-90 – Instruction manual surfaces 17. Oven door glass Oven with door 18. Oven thermometer Oven door hinge...
  • Page 14: Installation

    If the additional smoke uptake pipe is not used, maximum efficiency of the cooker, i.e. fuel is additionally assured ! SENKO cookers SG-75 and SG-90 – Instruction manual...
  • Page 15: Chimney Preparation And Control

    Smoke outlet pipe must not penetrate into the chimney clear opening (figure 6c). Differences between the proper and improper connection of the cooker to the chimney are displayed in the following figure. SENKO cookers SG-75 and SG-90 – Instruction manual...
  • Page 16 PROPER IMPROPER figure 6 SENKO cookers SG-75 and SG-90 – Instruction manual...
  • Page 17 7 (side or rear), and adjust the height and tighten the SENKO cookers SG-75 and SG-90 – Instruction manual screw the outer rosette...
  • Page 18: Fresh Air Vents

    The warranty will be void in case the damage to the parts listed before occurred from excessive oven temperature. 4.6. INSTALLATION TESTING Prior to initial firing it is necessary to check if the smoke uptake pipe is properly fastened. SENKO cookers SG-75 and SG-90 – Instruction manual...
  • Page 19: Handling The Product

    (14) Flue gas deflector (14) can also be used to regulate the oven temperature (7)  if the flue gas deflector is opened (pulled outwards), the oven is cooling. SENKO cookers SG-75 and SG-90 – Instruction manual...
  • Page 20: Air Adjustment And Regulation

    (minimum diameter 100 mm). The connecting pipe or the reduction must be made out of non-flammable material (in accordance with DIN 4102-B1). Figure 10 shows an example of reduction (reduction is not supplied with the cooker). SENKO cookers SG-75 and SG-90 – Instruction manual...
  • Page 21: Firebox Grate

    (nails, etc.), the grate cannot move. In this case it is necessary to clean the grate in order to be moved.  wide grate openings must be positioned facing upwards at all times to allow the ashes to fall down ! SENKO cookers SG-75 and SG-90 – Instruction manual...
  • Page 22: Firing

    Maximum quantity of fuel that can be accommodated in the firebox:  2-3 kg (wood); 1,5-2 kg (briquettes). Adding fuel in regular intervals, in quantities of 0,5 to 1 kg, is recommended. SENKO cookers SG-75 and SG-90 – Instruction manual...
  • Page 23: Adding Fuel

    1-2 cm between them. WARNING! New fuel quantities should be added only on top of embers, i.e., not on the flames, but only on top of embers (approx. 1 cm thick). SENKO cookers SG-75 and SG-90 – Instruction manual...
  • Page 24: Feeding In Transition Period

    5.5. OVEN DOOR Oven door are removed as shown in the following figure : SENKO cookers SG-75 and SG-90 – Instruction manual...
  • Page 25: Fuel Box

    5 mm and lightly pull towards yourself.  the box is mounted back by reversing the procedure ! Easily flammable or explosive objects must not be stored in the box ! SENKO cookers SG-75 and SG-90 – Instruction manual...
  • Page 26: Height Adjustment

    (1) and thoroughly clean the soot from the firebox, around the oven and flue gas deflector, including the chimney outlet opening (13). Cooker cleaning is to be performed only when the cooker is inactive and when it is cold ! SENKO cookers SG-75 and SG-90 – Instruction manual...
  • Page 27: Cleaning The Flue Gas Channel

     clean and remove the soot and ashes from the cooker inside (figure 17c and d) using a scoop. After thorough cleaning, mount back the protective lid and cleaning hatch lid back into their positions. slika 14 figure 17 SENKO cookers SG-75 and SG-90 – Instruction manual...
  • Page 28: Maintenance

    Only original spare parts by the manufacturer are to be used. Should non-original spare parts be used or should the repair be executed by an unauthorized individual, the warranty will be void. SENKO cookers SG-75 and SG-90 – Instruction manual...
  • Page 29: Malfunctions / Causes / Solutions

     chimney lower than quantity 4.5 m  adjust the chimney in  chimney diameter accordance with chapters 4.2. smaller than the one and 4.3. prescribed SENKO cookers SG-75 and SG-90 – Instruction manual...
  • Page 30: Technical Support

     warranty (at the back of this Manual),  written installation report (at the back of this Manual),  Instruction manual. The documents listed above are necessary to ensure the quickest and clearest removal of the occurring malfunction ! SENKO cookers SG-75 and SG-90 – Instruction manual...
  • Page 31: Technical Data

    The manufacturer withholds the right to change any technical specification to further improve the products SENKO cookers SG-75 and SG-90 – Instruction manual...
  • Page 32: Terms Of Warranty

    SENKO cookers SG-75 and SG-90 – Instruction manual The manufacturer SENKO d.o.o. withholds the right to alter any technical details, data and photographs published in this booklet without prior warning, for the purpose of improving its products. Photographs of the cooker, parts,...
  • Page 33: Warranty

    Servicing agency comments : ___________________________ ___________________________ ___________________________ ___________________________ Servicing completed on date : Servicing completed on date : ______________ ______________ Stamp and servicing Stamp and servicing SENKO kamini – Uputstvo za upotrebu ____________ ____________ technician signature : technician signature :...
  • Page 34: Installation Report

    Height (m): ……………………….. Draught (Pa): …………. Flue gases exit temperature (°C): ………… Last inspection date: ……………… Number of connections: ………………. Smoke venting pipe ( if connected Cross-section (mm): …………….. Length (m): …………… Number of elbows: ………..SENKO kamini – Uputstvo za upotrebu...
  • Page 35: Ce Marking

    Manufactured in the Republic of Croatia DECLARATION OF CONFORMITY This product is certified in accordance with the EN 12815. Test report number 30-11665/3 from June 29 , 2012. SENKO kamini – Uputstvo za upotrebu The original product Certificate and Declaration of Conformity available upon request.
  • Page 36 NOTES : ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ SENKO kamini – Uputstvo za upotrebu...
  • Page 37 SENKO kamini – Uputstvo za upotrebu...
  • Page 38 SENKO kamini – Uputstvo za upotrebu...
  • Page 39 SENKO kamini – Uputstvo za upotrebu...
  • Page 40 A HEALTHY ENVIRONMENT. You can find this Manual at http://en.senko.hr/ If you have any suggestions on how to improve this Manual or you have noticed any deficiency, feel free to contact us on tehnologija@senko.hr SN-EN-04/14 SENKO kamini – Uputstvo za upotrebu...