Dear client, thank you for choosing a SENKO cooker! This product was designed and manufactured to its minutest details in order to fulfill your every need for functionality and safety. Instruction manual This will teach you to operate your cooker properly, so please read the manual carefully before using the cooker.
E 2390 L SG-90 E 2390 D SG-90 are models from the SENKO cookers palette which can accommodate your needs in the best possible way. Therefore, we ask you to CAREFULLY READ THESE INSTRUCTIONS, which will help you to achieve the best possible results already during the initial use.
Page 6
cooker cleaning tool (23). Figure 1 CAUTION! The cooker weighs between 130 and 200 kg. Extra caution is necessary when unloading, transferring, moving and installing the cooker in order to avoid physical injury. Instruction manual SENKO cookers SG –...
it is necessary to use protective heat insulated gloves when adding fuel to the firebox protective heat insulated gloves must also be used when opening and closing the oven and firebox door and removing the tray from the oven and ash box. Instruction manual SENKO cookers SG –...
(backflow) because the counter pressure occurs here. Therefore, it is necessary to adhere to limitations Figure 2 listed in mechanical appliances for flue gases suction are not allowed. Instruction manual SENKO cookers SG –...
(rain, fog, snow, insolation period, etc.) the wind is most certainly the crucial one. Apart from the pressure caused by the temperature difference between the flue gases and the outer chimney air, there is another type of pressure – wind dynamic pressure. Instruction manual SENKO cookers SG –...
Page 10
(A). Contrary to that, underpressure can occur in lee rooms (C), adversely affecting functions of the chimney situated on the opposite side (D) from the wind direction. Instruction manual SENKO cookers SG –...
(the chimney-sweeper Manual must complete the installation report at the end of this Special attention must be paid that there is enough air for combustion being supplied to the room cooker is installed in. Instruction manual SENKO cookers SG –...
3. TECHNICAL FEATURES SENKO cookers SG are intended for cooking, baking and household heating. They are equipped with an oven just like the traditional kitchen cooker. Cookers are suitable for installation between other kitchen chapter 4.1. appliances (with ensuring minimum safety distances – see without heating risks.
Page 13
Cooker housing 23. Cooker cleaning tool 14. Flue gas deflector Lower door 15. Handle for grate moving Firebox door 16. Movable grate Oven with door Instruction manual SENKO cookers SG – 17. Oven door glass Oven door hinge 18. Oven thermometer...
Page 14
16. Firebox grate 17. Oven door glass 18. Oven thermometer 19. Door hinge bolt 20. Firebox door glass 21. Primary air inlet hatch 22. Chimney connection point extension Figure 5b 23. Cooker cleaning tool Instruction manual SENKO cookers SG –...
Floor protection Radiation area A cooker should not be placed in rooms where there are gas stoves or cookers, and in the bathroom, in buildings intended as laundries or Instruction manual SENKO cookers SG –...
Page 16
The distance between the cooker and kitchen element is intended for air circulation (cooling) – see the Figure above. Here also you should take care on how to ensure access to a cooker for maintenance and servicing. Instruction manual SENKO cookers SG –...
Smoke outlet pipe must not penetrate into the chimney clear Figure 6c opening ( Differences between the proper and improper connection of the cooker to the chimney are displayed in the following figure. Instruction manual SENKO cookers SG –...
Page 20
In doing so, you have remain the inner sheet metal! external sheet metal of the rosette and on some models only external lid (which are at the beginning removed from the cooker), as excess. Instruction manual SENKO cookers SG –...
Ø80mm (depending on the cooker model) on the rear side of the cooker, Figure 10 for the purpose of entering fresh outside air – see also Air supply Ø80 mm Ø80 mm Air supply supply supply Instruction manual SENKO cookers SG –...
Page 22
It is not permitted to install cut-off devices in the supply air duct (dampers, sliders, etc.). To prevent air from permanently flowing through the appliance when it is not in use, close the dampers in the appliance. Instruction manual SENKO cookers SG –...
The warranty will be void in case the damage to the parts listed before occurred from excessive oven temperature. 4.6. INSTALLATION TESTING Prior to initial firing it is necessary to check if the smoke uptake pipe is properly fastened. Instruction manual SENKO cookers SG –...
(14) closed flue gas deflector (14) Flue gas deflector (14) can also be used to regulate the oven temperature (7) if the flue gas deflector is opened (pulled outwards), the oven is cooling. Instruction manual SENKO cookers SG –...
80 mm). The connecting pipe or the reduction must be made out of non-flammable material (in accordance with DIN 4102-B1). Figure 10 shows an example of reduction (reduction is not supplied with the cooker). Instruction manual SENKO cookers SG –...
(15) which is located to the right of the left cooker firebox respectively, to the left of the right cooker firebox. By moving the grate can be further Figure 12 controlled a primary air inlet, for better Instruction manual SENKO cookers SG –...
300°C. Maximum quantity of fuel that can be accommodated in the firebox : 2-3 kg (wood); 1,5-2 kg (briquettes). Adding fuel in regular intervals, in quantities of 0,5 to 1 kg, is recommended. Instruction manual SENKO cookers SG –...
1-2 cm between them. WARNING! New fuel quantities should be added only on top of embers, i.e., not on the flames, but only on top of embers (approx. 1 cm thick). Instruction manual SENKO cookers SG –...
Figure 15 approx. 5 mm and lightly pull towards yourself. the box is mounted back by reversing the procedure! Easily flammable or explosive objects must not be stored in the box ! Instruction manual SENKO cookers SG –...
(1) and thoroughly clean the soot from the firebox, around the oven and flue gas deflector, including the chimney outlet opening (13). Cooker cleaning is to be performed only when the cooker is inactive and when it is cold! Instruction manual SENKO cookers SG –...
clean and remove the soot and ashes from the cooker inside ( Figure ) using a scoop. After thorough cleaning, mount back the protective lid and cleaning hatch lid back into their positions. slika 14 Figure 17 Instruction manual SENKO cookers SG –...
6.1.2. COOKER SG-60 When cleaning the flue gas channel, adhere to the following procedure: remove the cooking plate (1), remove the grate (16) from the firebox Figure 18a by unscrewing the 4 screws remove the protective lid and clean the area underneath ...
SPARE PARTS Only original spare parts by the manufacturer are to be used. Should non-original spare parts be used or should the repair be executed by an unauthorized individual, the warranty will be void. Instruction manual SENKO cookers SG –...
4.3. adjust the chimney flue insufficient or excessive Cooking and baking draught in accordance with chimney flue draught temperature too chapter 4.2. excessive primary air volume reduce primary air volume Instruction manual SENKO cookers SG –...
warranty (at the back of this Manual written installation report (at the back of this Instruction manual. The documents listed above are necessary to ensure the quickest and clearest removal of the occurring malfunction! Instruction manual SENKO cookers SG –...
11. TERMS OF WARRANTY These warranty conditions are valid in all European countries, in which SENKO products are sold. The client addresses the manufacturer/dealer or the nearest authorized servicing agent for all complaints; providing the purchase receipt with the date of purchase, warranty and installation report in the process.
Number of connections: ………………. Smoke venting pipe ( Air supply pipe ( if connected if connected Cross-section (mm): …………….. Cross-section (mm): …………….. Length (m): …………… Length (m): …………… Number of elbows: ………..Number of elbows: ………..SENKO kamini – Uputstvo za upotrebu...
Manufactured in the Republic of Croatia DECLARATION OF CONFORMITY This product is certified in accordance with the EN 12815. Test report number 30-11665/3 from June 29 , 2012. The original product Certificate and Declaration of Performance available upon request. SENKO kamini – Uputstvo za upotrebu...
Page 44
… THE SPIRIT OF TRADITION IN MODERN FORMS FOR A HEALTHY ENVIRONMENT. You can find this Manual at http://en.senko.hr/ SENKO kamini – Uputstvo za upotrebu...
Need help?
Do you have a question about the SG-60 and is the answer not in the manual?
Questions and answers