SENKO SG-50 Instruction Manual

Hide thumbs Also See for SG-50:

Advertisement

Quick Links

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SG-50 and is the answer not in the manual?

Questions and answers

Summary of Contents for SENKO SG-50

  • Page 2 Instruction manual - INSTALLATION you will learn to correctly install the product, and using the Instruction manual - HANDLING you will learn to use the product Both manuals can be found at http://en.senko.hr/, or you can request them at info@senko.hr. Senko managment...
  • Page 3: Table Of Contents

    CLEANING ..................................13 5.1. CLEANING THE FLUE GAS CHANNEL ......................... 14 5.1.1. COOKERS SG-50, SG-60 and SG-60 PREMIUM - cleaning above the oven ............14 5.1.2. COOKER SG-50 ....................................14 5.1.3. COOKER SG-60 and SG-60 PREMIUM ..........................15 5.1.4. COOKERS SG-75 and SG-90 ..............................15 MAINTENANCE ................................
  • Page 4: General

    � SG-75L/D � SG-90L/D are models from the SENKO cookers palette which can accommodate your needs in the best possible way. Therefore, we ask you to CAREFULLY READ THESE INSTRUCTIONS, which will help you to achieve the best possible results already during the initial use.
  • Page 5: Fuel

    13384 and all other standards for the chimney dimensioning)! � The chimney has a very important function of the smoke exhaust at solid fuel heating devices and therefore MUST BE well and properly dimensioned! SENKO cookers SG - Instruction manual - HANDLING...
  • Page 6: Chimney Cap

    Descending wind ALWAYS has the effect of decreasing the draught � overpressure occurs. Apart from wind direction and velocity, chimney position in relation to the house roof and surrounding area is also important (Figure 3). SENKO cookers SG - Instruction manual - HANDLING...
  • Page 7: Insulation

    Cooker is to the outer surfaces isolated with chamotte plates 40 mm thick. The sides are chamber derived and cooled with the natural air circulation. The depth of the chamber is 25 mm. SENKO cookers SG - Instruction manual - HANDLING...
  • Page 8: Warnings And Safety

    3. TECHNICAL FEATURES SENKO cookers SG are intended for cooking, baking and household heating. They are equipped with an oven just like the traditional kitchen cooker. Cookers are suitable for installation between other kitchen appliances (with ensuring minimum safety distances – see Instruction manual - INSTALLATION).
  • Page 9 15. Firebox door handle 22. Chimney connection point 6. Firebox door 16. Firebox grate extension 7. Oven with door 17. Oven door glass 23. Cooker cleaning tool 8. Oven door hinge 18. Oven thermometer SENKO cookers SG - Instruction manual - HANDLING...
  • Page 10 18. Oven thermometer 19. Door hinge bolt 20. Firebox door glass 21. Primary air inlet hatch 22. Chimney connection point extension 23. Cooker cleaning tool RIGHT COOKER SG - pogled sa bočne strane SENKO cookers SG - Instruction manual - HANDLING...
  • Page 11: Handling The Product

    If the chimneyis equipped with a vent damper, it must be adjusted to keep the chimney flue draught within the limitations 12 ± 2 Pa. PRIMARY AIR – cookers SG-50, SG-60 and SG-60 PREMUIM Primary air is the air that flows directly through the firebox grate.
  • Page 12: Secondary Air

    At cookers SG-50, SG-60 and SG-60 PREMIUM the regulation of secondary air is automatic through the holes (Figure 10).
  • Page 13: Firebox Grate

    Cooker optimum values may be achieved only if the cooker nominal power was chosen in accordance with the rules of profession and object energetic efficiency. SENKO cookers SG - Instruction manual - HANDLING...
  • Page 14: Adding Fuel

    � move the safety all the lean against the door toward the cooker slits way back on the left and pull the door from the � cooker hinge bearing SENKO cookers SG - Instruction manual - HANDLING...
  • Page 15: Cleaning

    (13). Cooker cleaning is to be performed only when the cooker is inactive and when it is cold ! SENKO cookers SG - Instruction manual - HANDLING...
  • Page 16: Cleaning The Flue Gas Channel

    5.1. CLEANING THE FLUE GAS CHANNEL 5.1.1. COOKERS SG-50,SG-60 and SG-60 PREMIUM - cleaning above the oven When cleaning the flue gas channel, adhere to the following procedure : remove the cooking plate, remove the frame from the � firebox into the space under the firebox/frame by unscrewing...
  • Page 17: Cooker Sg-60 And Sg-60 Premium

    (Figure 21c and d) using a cooker cleaning tool (23). After thorough cleaning, mount back the protective lid and cleaning hatch lid back into their positions. SENKO cookers SG - Instruction manual - HANDLING...
  • Page 18: Maintenance

    Only original spare parts by the manufacturer are to be used. Should non-original spare parts be used or should the repair be executed by an unauthorized individual, the warranty will be void. SENKO cookers SG - Instruction manual - HANDLING...
  • Page 19: Malfunctions / Causes/ Solutions

    � use fuel as described in chapter 1.1. temperature too high closed � open the flue gas deflector � grate in the fully open � adjust opennessof the grate as position required SENKO cookers SG - Instruction manual - HANDLING...
  • Page 20 MODERN FORMS FOR A HEALTHY ENVIRONMENT. You can find Instruction manual - INSTALLATION and Instruction manual - HANDLING http://en.senko.hr/ We reserve the right to change all figures, technical details and colours of products mentioned in this manual without prior notice.

This manual is also suitable for:

Sg-60Sg-60 premiumSg-75Sg-90

Table of Contents