3.2.2

Setting Dip Switches

FIGURE 12: EXAMPLE: DIP SWITCH #1 SHOWN IN 'ON' POSITION
Note: Use care when changing dip switch settings. Carefully use a pointer on the dip switch
you are going to change. DO NOT use a screw driver or apply excessive force.
3.2.3

Dip Switch Functions

Note: (Developer's refer to Programming Manual for more information)
Dip Switch
Function
1 & 2
Communication Interface
Bluetooth
3 & 4 & 5
Baud Rate
6
Parity Bit
Parity Enabled
Parity Disabled
7
Odd/Even
Even Parity Checker
Odd Parity Checker
8
Auto Power Save
Power Save Disabled
Power Save Enabled
Note: In order for changes to the dip switch configuration to take effect, the printer power
must be reset. This action occurs automatically when the battery is removed to gain access
to the dip switches.
ON
1 2 3 4 5 6 7 8
Table 2 – DIP Switch Setting
Switch #
SW 1
RS232
OFF
IrDA
ON
OFF
802.11b
ON
SW 3
57600
OFF
38400
OFF
19200
ON
14400
OFF
9600
ON
2400
OFF
1200
ON
SW 6
ON
OFF
SW 7
ON
OFF
SW 8
OFF
ON
Switch #
Switch #
SW 2
OFF
OFF
ON
ON
SW 4
SW 5
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
ON
ON
ON
ON
ON
11
Notes
Baud rate set by Dip switches 3,4 and 5
Baud Rate can be negotiated up to the value
specified through Dip switches 3,4 and 5
BT Baud Rate set for 57600 bps.
Dip switches 3,4 and 5 must be set to OFF
position
802.11 Baud Rate set for 57600 bps
Dip switches 3,4 and 5 must be set to OFF
position
Use for fixed IrDA
Does not apply for IrDA
Does not apply for IrDA
Does not apply for IrDA
Does not apply for IrDA
Manual On/Off
Auto Power Down