Indoor Use; System Specifications; Power Requirements; Environmental Requirements - DCI LLC DigiTrak F Series Operator's Manual

Table of Contents

Advertisement

Indoor Use

This battery charger is designed for indoor use only and should not come into contact with
water or extreme dust. To avoid overheating, do not cover the charger while in use. Using it
to charge any other type of battery other than a DCI battery pack can result in damage and
void the battery charger warranty.

System Specifications

The power requirements, environmental requirements, and equipment maintenance
requirements for the FBC F Series Battery Charger are listed below.

Power Requirements

Device (Model Number)
DigiTrak F Series Battery
Charger (FBC)

Environmental Requirements

Device
DigiTrak F Series Battery
Charger (FBC)
DigiTrak F Series Lithium-Ion
Battery Pack (FBP)
System working altitude: up to 6561 ft. (2000 m).
FBC Operator's Manual
DigiTrak
D
C
IGITAL
ONTROL
Operational Voltage
Input
10–28 V
Output 19.2 V
Relative Humidity
<99% for 32–50° F (0–10° C)
<95% for 50–95° F (10–35° C)
<99% for < 50° F (10° C)
<95% for 50–95° F (10–35° C)
<75% for 95–140° F (35–60° C)
I
NCORPORATED
Operational Current
5.0 A max
1.8 A max
Operating Temperature
32 to 95° F (0 to 35° C)
-4 to 140° F (-20 to 60° C)
5