Resetting the ePMP to factory defaults by power cycling

Operators may reset an ePMP radio to default factory configuration by a sequence of power
cycling (removing and re-applying power to the device). This procedure allows operators to
perform a factory default reset without a tower climb or additional tools. The procedure is depicted
in Figure 63.
Procedure:
1
Remove the Ethernet cable from PoE jack of the power supply for at least 10 seconds.
Reconnect the Ethernet cable to re-supply power to the ePMP device for 3-5 seconds and
2
disconnect cable to power off the ePMP device for 3-5 seconds. (1
Reconnect the Ethernet cable to re-supply power to the ePMP device for 3-5 seconds and
3
disconnect cable to power off the ePMP device for 3-5 seconds. (2
Reconnect the Ethernet cable to re-supply power to the ePMP device for 3-5 seconds and
4
disconnect cable to power off the ePMP device for 3-5 seconds. (3
Reconnect the Ethernet cable to re-supply power to the ePMP device for 3-5 seconds and
5
disconnect cable to power off the ePMP device for 3-5 seconds. (4
6
Reconnect the Ethernet cable to re-supply power to the ePMP device for at least 30 seconds
and allow it to go through the boot up procedure (Note: Device will go through an additional
reset automatically). This will reset the current configuration files to factory default
configuration (e.g. IP addresses, Device mode, RF configuration etc.). The device can be
pinged from a PC to check if boot up is complete (Successful ping replies indicates boot up is
complete).
7
Access the ePMP device using the default IP address of 192.168.0.1 (AP) or 192.168.0.2 (SM).
Figure 63 Power cycle timings
Where:
V+(ON)
Off
t
on
t
off
Is:
Power through PoE has been applied to the device
Power through PoE has been removed from the device
Time duration for which the device has been powered
on. This should be 3-5 seconds.
Time duration for which the device has been powered
off. This should be 3-5 seconds.